1102
Brocade Network Advisor SAN User Manual
53-1003154-01
Bottleneck detection
28
NOTE
A bottleneck cleared alert is sent if you disable bottleneck detection on a bottlenecked port, even
though the port is still bottlenecked.
Bottlenecks can be highlighted in the Connectivity Map and Product List. Select Monitor >
Performance > View Bottlenecks. If a port is experiencing a bottleneck, a bottleneck icon is
displayed in the Connectivity Map for the switch and fabric, and in the Product List for the port,
switch, and fabric, as shown in
Figure 482
. In the figure, port15 and port22 are bottlenecked.
FIGURE 482
Bottleneck port indications
Limitations of bottleneck detection
The bottleneck detection feature for latency detection is not recommended for link utilizations
above 85 percent.
The bottleneck detection feature detects latency bottlenecks only at the point of egress, not
ingress. For example, for E_Ports, only the traffic egressing the port is monitored. For FCoE ports,
bottleneck detection monitors traffic going from the FC side to the DCB side, and does not monitor
traffic going in the reverse direction.
Enabling bottleneck alerts and configuring alert parameters
Bottleneck detection is enabled on a switch or fabric basis. It enables both latency and congestion
detection. Consider these points when enabling bottleneck detection:
•
If you enable bottleneck detection on a fabric, the feature is applied to all eligible switches in
the fabric and all eligible ports on the switches.
•
If you enable bottleneck detection on a switch, the feature is applied to all eligible ports on that
switch.
•
You can override switch configuration by changing parameters for specific ports.
•
When changing switch-level parameters, such as time and severity threshold values,
bottleneck detection will be disabled, then enabled.
If ineligible ports later become eligible or, in the case of a logical switch, if ports are moved to the
logical switch, bottleneck detection is automatically applied to those ports.
If you add additional switches, including logical switches, to the fabric, bottleneck detection is not
automatically applied, so be sure to enable bottleneck detection on those switches as well.
NOTE
It is recommended that you enable bottleneck detection on every switch in the fabric.
Summary of Contents for Network Advisor 12.3.0
Page 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Page 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Page 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Page 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Page 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Page 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Page 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Page 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Page 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Page 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Page 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Page 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Page 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Page 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Page 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Page 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Page 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Page 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...