1MAC050144-MB C
Section 13
Technical data
615 series ANSI
691
Technical Manual
Section 13
Technical data
Table 565: Dimensions
Table 566: Power supply
Description
Value
Width
frame
7.08 inches (179.8 mm)
case
6.46 inches (164 mm)
Height
frame
6.97 inches (177 mm), 4U
case
6.30 inches (160 mm)
Depth
7.64 inches (194 mm)
Weight
complete IED
7.7 lbs (3.5 kg)
plug-in unit only
4.0 lbs (1.8 kg)
Description
Type 1
Type 2
V
aux
100, 110, 120, 220, 240 V AC, 50 and
60 Hz
24, 30, 48, 60 V DC
48, 60, 110, 125, 220, 250 V DC
Maximum interruption time in
the auxiliary DC voltage
without
resetting the IED
50 ms at V
aux
rated
V
aux
variation
38...110% of V
n
(38...264 V AC)
50...120% of V
n
(12...72 V DC)
80...120% of V
n
(38.4...300 V DC)
Start-up threshold
19.2 V DC (24 V DC * 80%)
Burden of auxiliary voltage
supply under quiescent (P
q
)/
operating condition
DC < 12.0 W (nominal)/< 18.0 W
(max)
AC< 16.0 W (nominal)/< 21.0W
(max)
DC < 12.0 W (nominal)/< 18.0
W
(max)
Ripple in the DC auxiliary
voltage
Max 15% of the DC value (at frequency of 100 Hz)
Fuse type
T4A/250 V
Summary of Contents for 615 Series ANSI
Page 1: ...Relion Protection and Control 615 series ANSI Technical Manual ...
Page 2: ......
Page 29: ...1MAC050144 MB C Section 615 series ANSI 22 Technical Manual ...
Page 389: ...Section 4 1MAC050144 MB C Protection functions 382 615 series ANSI Technical Manual ...
Page 485: ...Section 6 1MAC050144 MB C Supervision functions 478 615 series ANSI Technical Manual ...
Page 635: ...Section 10 1MAC050144 MB C Other functions 628 615 series ANSI Technical Manual ...
Page 711: ...Section 16 1MAC050144 MB C Glossary 704 615 series ANSI Technical Manual ...
Page 712: ......