1MAC050144-MB C
Section 1
Introduction
615 series ANSI
29
Technical Manual
Frequency protection, instance 4
FRPFRQ4
f>/f<,df/dt (4)
81-2 (1)
Voltage per hertz protection, instance 1
OEPVPH1
U/f> (1)
24
24-1 (2)
Voltage per hertz protection, instance 2
OEPVPH2
U/f> (2)
24-2 (2)
Voltage per hertz protection, instance 3
OEPVPH3
U/f> (3)
24-1 (1)
Voltage per hertz protection, instance 4
OEPVPH4
U/f> (4)
24-2 (1)
Three-phase thermal protection for feeders, cables
and distribution transformers, Instance 1
T1PTTR1
3Ith>F (1)
49F-1
Three-phase thermal protection for feeders, cables
and distribution transformers, Instance 2
T1PTTR2
3Ith>F (2)
49F-2
Three-phase thermal overload protection for power
transformers, two time constants
T2PTTR1
3Ith>T
49T-1
Negative-sequence overcurrent protection for
motors, instance 1
MNSPTOC1
I2>M (1)
46M-1
Negative-sequence overcurrent protection for
motors, instance 2
MNSPTOC2
I2>M (2)
46M-2
Loss of load supervision, instance 1
LOFLPTUC1
3I< (1)
37M-1
Loss of load supervision, instance 2
LOFLPTUC2
3I< (2)
37M-2
Motor load jam protection
JAMPTOC1
Ist>
51LR
Motor start-up supervision
STTPMSU1
Is2t n<
66/51LRS
Phase reversal protection
PREVPTOC1
I2>>
46R
Thermal overload protection for motors
MPTTR1
3Ith>M
49M
Motor differential protection
MPDIF1
3dl>M
87M
Stabilized and instantaneous differential protection
for 2W –transformers
TR2PTDF1
3dI>T
87T
Numerical stabilized low impedance restricted
ground-fault protection
LREFPNDF1
dIoLo>
87LOZREF
87LOZREF (2)
Circuit breaker failure protection, instance 1
CCBRBRF1
3I>/Io>BF (1)
50BF-1
50BF
50BF-1
Circuit breaker failure protection, instance 2
CCBRBRF2
3I>/Io>BF (2)
50BF-2
50BF-2
Three-phase inrush detector, instance 1
INRPHAR1
3I2f> (1)
INR-1
Three-phase inrush detector, instance 2
INRPHAR2
3I2f> (2)
INR-2
Master trip, instance 1
TRPPTRC1
Master Trip (1)
86/94-1
86/94-1
86/94-1
Master trip, instance 2
TRPPTRC2
Master Trip (2)
86/94-2
86/94-2
86/94-2
Arc protection, instance 1
ARCSARC1
ARC (1)
AFD-1
AFD-1
AFD-1 (2)
Arc protection, instance 2
ARCSARC2
ARC (2)
AFD-2
AFD-2
AFD-2 (2)
Arc protection, instance 3
ARCSARC3
ARC (3)
AFD-3
AFD-3
AFD-3 (2)
High impedance fault detection
PHIZ1
PHIZ1
HIZ
Multi-purpose protection, instance 1
2)
MAPGAPC1
MAP (1)
MAP 1
MAP 1
Multi-purpose protection, instance 2
2)
MAPGAPC2
MAP (2)
MAP 2
MAP 2
Table continued on next page
Standard configuration functionality
IEC 61850
IEC 60617
ANSI/C37.2 - 2008
REF615
REM615
RET615
Summary of Contents for 615 Series ANSI
Page 1: ...Relion Protection and Control 615 series ANSI Technical Manual ...
Page 2: ......
Page 29: ...1MAC050144 MB C Section 615 series ANSI 22 Technical Manual ...
Page 389: ...Section 4 1MAC050144 MB C Protection functions 382 615 series ANSI Technical Manual ...
Page 485: ...Section 6 1MAC050144 MB C Supervision functions 478 615 series ANSI Technical Manual ...
Page 635: ...Section 10 1MAC050144 MB C Other functions 628 615 series ANSI Technical Manual ...
Page 711: ...Section 16 1MAC050144 MB C Glossary 704 615 series ANSI Technical Manual ...
Page 712: ......