BALANCE RING INSTALLATION INSTRUCTIONS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
1.
Disconnect electrical power before servicing the wash-
er.
2.
Remove the control panel retaining screws and flip
up the control panel into the service position.
3.
Remove the cabinet retaining clips; unplug the lid
switch harness and any other additional harnesses
(coinop models) that are necessary to remove the
cabinet. Additionally on coinop models the front pan-
el and side panel retaining screws must be removed.
4.
Lift the cabinet away from the washer.
5.
Release the air brake from the washer back panel,
then the tub ring from the outer tub.
6.
Slowly lift the balance ring from the washbasket, make
sure all 8 balance ring-retaining clips are accounted
for. Retaining clips can damage the pump impeller if
drawn into the pump. Inspect the outer tub and pump
impeller for damage. Replace the outer tub (part num-
ber 63125) and pump (part number 3363394) if ei-
ther part shows signs of damage. If all 8 retaining
clips are accounted for, skip to step 10. If all 8 clips
are not located, continue to step 7.
7.
Remove the agitator cap and retaining bolt, then re-
move the agitator.
8.
Remove the washbasket spanner nut using the ap-
propriate spanner wrench.
9.
Apply downward pressure to the edge of the wash-
basket to release it from the drive block, then remove
the washbasket from the washer. Check the outer tub
for the remaining missing balance ring retaining clips.
10. Set the balance ring onto the washbasket. Once
placed onto the basket, apply downward pressure to
the balance ring with both hands to insure the bal-
ance ring is locked onto the basket. Move your hands
90° to where pressure was first applied and apply
pressure on the balance ring again. Do not spin the
balance ring independently from the washbasket! This
may damage the new clips!
11. If the washbasket has been removed from the wash-
er turn the basket and balance ring assembly over so
the balance ring is in contact with the floor. Apply pres-
sure onto the bottom of the washbasket to ensure the
balance ring is properly seated on the washbasket.
Reinstall washbasket, spanner nut and agitator.
12. Re install the tub ring and air brake. Replace the tub
ring (part number 3360611) if it shows signs of dam-
age.
13. Reinstall the cabinet, cabinet clips and wiring harness
connections. Reinstall the side panel mounting screws
and front access panel on models so equipped.
14. Close the control panel and reinstall the control panel
mounting screws.
PRESS DOWN IN
LOCATIONS AS
ILLUSTRATED.
DO NOT ROTATE
BASKET
INDEPENDENTLY
OF BALANCE RING
DURING
INSTALLATION
Содержание ADVANTECH CAE2761K
Страница 8: ...1 4 ...
Страница 9: ...1 5 ...
Страница 10: ...1 6 ...
Страница 11: ...1 7 ...
Страница 12: ...1 8 ...
Страница 14: ...1 10 NOTES ...
Страница 15: ...WASHER 2 1 ...
Страница 22: ...2 8 ...
Страница 29: ...2 15 Whirlpool Pt 3391910 ...
Страница 42: ...2 28 ...
Страница 54: ...2 40 ...
Страница 68: ...4 10 285784 ...
Страница 146: ...6 18 NOTES ...
Страница 147: ...Full Console Model Metercase Model 7 1 Coinslide Switch Service Switch Coin vault Switch Battery Jumper ...
Страница 148: ...Full Console Model 7 2 ...
Страница 149: ...Full Console Model 7 3 ...
Страница 150: ...7 4 Stack Electric Dryers ...
Страница 151: ...7 5 Stack Gas Dryers 1 2 4 5 3 TERMINALS RESISTANCE 1 to 2 1365Ω 25 1 to 3 560Ω 25 4 to 5 1220Ω 50 ...
Страница 153: ...8 1 ...
Страница 154: ...8 2 ...
Страница 155: ...9 1 ...
Страница 156: ...9 2 ...
Страница 157: ...9 3 ...
Страница 158: ...9 4 ...
Страница 159: ...9 5 ...
Страница 174: ... NOTES ...
Страница 175: ... NOTES ...
Страница 176: ... NOTES ...
Страница 178: ...CORPORATION ...