AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
174
FC.13
PLC Step 14
0.00-320.00Hz
40.00Hz
●
137 0xC0D
FC.14
PLC Step 15
0.00-320.00Hz
30.00Hz
●
137 0xC0E
FC.15
PLC running
Mode selection
LED“0”digit:
0: Stop after single cycle
1: Continuous cycles
2: Keep final value after single cycle
LED“10”digit: Time unit
0: second
1: minute
2: hour
LED“100”digit: Power down memory
mode
0: no saved
1: save
LED“1000”digit:
Start-up mode
0: Restart from the 1
st
step
1: Restart from the stop stage
2: Continue from the time when stop
LED“0000”digit:
Start-up mode
0: Restart from the 1
st
step
1: Restart from the step
where stop
2: Restart from the time
when stop
0000
●
139 0xC0F
FC.16
PLC 1st step running
time
0.0-6500.0(s/m/h) 10.0
●
140 0xC10
FC.17
PLC 2nd step running
time
0.0-6500.0(s/m/h) 10.0
●
140 0xC11
FC.18
PLC 3rd step running
time
0.0-6500.0(s/m/h) 10.0
●
140 0xC12
FC.19
PLC 4th step running
time
0.0-6500.0(s/m/h) 10.0
●
140 0xC13
FC.20
PLC 5th step running
time
0.0-6500.0(s/m/h) 10.0
●
140 0xC14
FC.21
PLC 6th step running
time
0.0-6500.0(s/m/h) 10.0
●
140 0xC15
FC.22
PLC 7th step running
time
0.0-6500.0(s/m/h) 10.0
●
140 0xC16
FC.23
PLC 8th step running
time
0.0-6500.0(s/m/h) 10.0
●
140 0xC17
FC.24
PLC 9th step running
time
0.0-6500.0(s/m/h) 10.0
●
141 0xC18