AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
157
F4.11
The display content of
the first line at the
running state
LED“0”digit: display the first group
0: Given frequency
1: Output frequency
2: Output current
3: Input voltage
4: Output voltage
5: Machine speed
6: Reserved
7: Output torque
8: PID given value
9: PID feedback value
A: Output power
B: Bus voltage
C: Module temperature 1
D: Module temperature 2
E: ON/OFF state of input terminal X
F: ON/OFF state of input terminal Y
LED“10”digit: display the second group
LED“100”digit: display the third group
LED“1000” digit: display the fourth
group
3210
●
102 0x40B
F4.12
The display content of
the first line at the
stopped state
LED “0” digit: display the first group
LED“00”digit:display the second group
LED“000” digit: display the third group
LED“0000”digit:display the fourth group
3210
●
102 0x40C
F4.13
The display content of
the second line at the
running state
LED “0” digit: display the first group
LED“00”digit:display the second group
LED“000” digit: display the third group
LED“0000”digit:display the fourth group
3210
●
102 0x40D
F4.14
The display content of
the second line at the
stopped state
LED “0” digit: display the first group
LED“00”digit:display the second group
LED“000” digit: display the third group
LED“0000”digit:display the fourth group
3210
●
102 0x40E
F4.15
Rotate speed display
coefficient
0.0-5000.0% 100.0%
●
102 0x40F