AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
111
Upper
frequency limit
selection
under torque
control
0: FWD/REV set by[F0.10]
1: FWD set by LED “00”digit
REV set by LED “000”digit
Give frequency
limit range
Feature
FWD/REV upper/lower limit all setby F0.10
Set FWD upper/lower limit separately
LED “0” digit: Torque control upper frequency limit selection
0: FWD/REV set by
[F0.11]
. Same as speed control
1: FWD set by LED “00”digit; REV set by LED “000”digit. Used where need set FWD upper/lower limit separately
LED “00” digit: FWD upper frequency limit set
0: Torque control FWD upper frequency limit No set (F7.24) + max frequency
*
torque control FWD upper frequency limit
bias.
1: Keyboard pot give +max frequency
*
torque control FWD upper frequency limit bias.
2:VS1 give +max frequency
*
torque control FWD upper frequency limit bias.
3:VS2 give +max frequency
*
torque control FWD upper frequency limit bias.
4: AS give +max frequency
*
torque control FWD upper frequency limit bias.
5: PUL give +max frequency
*
torque control FWD upper frequency limit bias.
6:RS485 give +max frequency
*
torque control FWD upper frequency limit bias.
LED “000” digit: REV upper frequency limit set
0: Torque control REV upper frequency limit No set (F7.26) + max frequency
*
torque control REV upper frequency limit
bias.
1: Keyboard pot give +max frequency
*
torque control REV upper frequency limit bias.
2:VS1 give +max frequency
*
torque control REV upper frequency limit bias.
3:VS2 give +max frequency
*
torque control REV upper frequency limit bias.
4: AS give +max frequency
*
torque control REV upper frequency limit bias.
5: PUL give +max frequency
*
torque control REV upper frequency limit bias.
6:RS485 give +max frequency
*
torque control REV upper frequency limit bias.
F7.24
Torque control FWD upper
frequency limit No set
Setting range: Lower limit-Max output
frequency
Factory set: 50.00
F7.25
Torque control FWD upper
frequency limit bias
Setting range: 0.0-20.0%
Factory set:0.0