![Veichi AC90 Скачать руководство пользователя страница 183](http://html1.mh-extra.com/html/veichi/ac90/ac90_manual_3940545183.webp)
AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
178
Monitor code
NO.
Function name
Range of settings and definition
Communication add
C-00 Given
frequency
0.01Hz
2100H
C-01 Output
frequency
0.01Hz
2101H
C-02 Output
current
0.1A
2102H
C-03 Input
voltage
0.1V
2103H
C-04 Output
voltage
0.1V
2104H
C-05 Machine
speed
RPM
2105H
C-06 Set
torque
0.1%
2106H
C-07 Output
torque
0.1%
2107H
C-08 PID
given
0.1%
2108H
C-09 PID
feedback
0.1%
2109H
C-10 Output
power
0.1%
210AH
C-11 Bus
voltage
0.1V
210BH
C-12
Module temperature 1
0.1
℃
210CH
C-13
Module temperature 2
0.1
℃
210DH
C-14
Input terminal X on-state
refer to diagram x
210EH
C-15
Output terminal Y on-state
refer to diagram x
210FH
C-16
Analog VS1 input
0.001V
2110H
C-17
Analog VS2 input
0.001V
2111H
C-18 Analog
AS
input
0.001mA
2112H
C-19
Impulse single PUL input
0.001kHz
2113H
C-20 Analog
output
AO1
0.01V
2114H
C-21 Analog
output
AO2
0.01V/0.01mA/0.01kHz 2115H
C-22
Counting value of counter
2116H
C-23
Running time after electrify(of
this time)
Hour 2117H
C-24
Local accumulative running time
0.1h
2118H
C-25
Inverter power class
kW
2119H
C-26
Inverter rated voltage
V
211AH
C-27
Inverter rated current
A
211BH
C-28 Software
edition
211CH
C-29
PG feedback frequency
0.01Hz
211DH