AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
87
5: REV JOG
6: Free stop
While it is valid, inverter stops output. Motor will free run.While free stop terminal is always valid; inverter
does not accept any start order and keep stop state. Whether recover to original order after free stop order is relieved
while terminal 2 line control running, refer to
[F2.13]
please. It does not recover to original order after free stop order is
relieved while keyboard, RS485, optional card and terminal 3 line control running. If need start inverter, it needs to input
run order again.
7: Emergency stop
If input emergency stop order while running, inverter DEC and stop according
[F1.24]
DEC time
seting. Details refer to
[F1.24]
. It can not run again before totally stopping. While
[F1.07]
is set as free stop, emergency
stop order and free stop order is same function. Once this terminal is valid, inverter stops output and free stop
immediately. If emergency stop terminal is always valid, inverter does not accept start order and keep stop. Under 2 line
control mode, whether recover original run order after relieve emergency stop order is decided by
[F2.13]
. Not recover
original order under keyboard, RS485, optional card and terminal 3 line control mode. If need start inverter, please input
order again.
Note: While use emergency stop function, please set right [F1.24] DEC time or work with energy brake function.
Otherwise over-voltage fault maybe happen.
8: Fault reset
It decides whether reset fault while alarm. Whether recover orginal order after fault reset is decided by
[F2.13]
.
9: Out fault input
Inverter stop output while accept exterior fault input signal by it. Motor free run and display
malfunction information E.EF.
10: Frequency (UP)
11: Frequency (DW)
Only valid while
[F0.03]
is set as 7. Details refer to
[F0.03]
.
12: (UP/DW clear)
Only valid while
[F0.03]
is set as 7. Details refer to
[F0.03]
.
13: Reserved
14: Reserved
15: Multi steps terminal 1
16: Multi steps terminal 2
17: Multi steps terminal 3
18: Multi steps terminal 4
See parameter details of multi steps and FC group of PLC.
19: ACC/DEC time selection terminal 1
20: ACC/DEC time selection terminal 2