AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
123
Linear speed selection terminal
linear speed setting
OFF
Linear speed setting 1
ON
Linear speed setting 2
F9.30
Current linear speed
Setting range:0.0-6500.0m/Min Factory
set:
*
Monitor the current linear speed in real time.
F9.31
Traction roller diameter
Setting range:0.0-1000.0mm Factory
set:100.0mm
F9.32
Traction roller pulse per
cycle
Setting range:1-60000
Factory set:1
While
[
F9.25
]
Linear input resource is 6, inverter gains traction linear speed by detection traction roller pulse signal. It
needs traction roller pulse per cycle and traction roller diameter.
Traction roller pulse per cycle: Nos of pulse per cycle of the traction roll in winding process.
F9.33 -F9.35
Reserved
Thickness calculate:
F9.36
Pulse per cycle
Setting range:1-60000
Factory set:1
F9.37
Cycles per layer
Setting range:1-10000
Factory set:1
While roll diameter calculation selection
[F9.11]
is 2,
[F9.36-F9.41]
are valid. PUL port is pulse input port default.
Inverter calculates the thickness by pulse from PUL port.
Pulse per cycle:
Pulse is coming from one cycle in winding process.
Cycles per layer:
Cycles which are needed for one layer of winding roll finish.
F9.38 Max
thickness
Setting range:0.01-100.00mm
Factory set:1.00
Max thickness of material permit. While thickness is analog input, max analog input corresponds to the max thickness.
And they are linear relationship.
F9.39
Material thickness set
resource
Setting range:0-5
Factory set: 0
It is used to select material thickness gain mode:
0: F9.40/F9.41 terminal select Select material thickness by terminals switch. details see
[F9.40-F9.41]
.
1: Keyboard potentiometer gives and modifies the material thickness.
2: VS1 gives and modifies the material thickness.
3: VS2 gives and modifies the material thickness.
4: AS gives and modifies the material thickness.
5: PUL gives and modifies the material thickness.