AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
155
F3.22
A01 output selection
0: Set frequency
1: running frequency
2: Output current
3: Input voltage
4: Output voltage
5: Run speed
6: Set torque
7: Output torque
8: PID give
9: PID feedback
10: Set tension
11: Bus voltage
12: Current roll diameter
13: VS2 input
14: Time per roll
15: Reserved
16: VS1 input
17: VS2 input
18: AS input
19: PUL input
0
●
97 0x316
F3.23
A02 output selection
1
●
97 0x317
F3.24
A01 output gain
25.0~200.0%
100.0%
●
98 0x318
F3.25
A01 output signal
bias
-10.0~10.0% 0.0%
●
98 0x319
F3.26
AO2 signal selection
0: 0-10V
1: 4.00-20.00mA
2: 0.00-20.00mA
3: Frequency pulse output
0
●
99 0x31A
F3.27
A02 output gain
25.0~200.0%
100.0%
●
99 0x31B
F3.28
A02 output signal
bias
-10.0~10.0% 0.0%
●
99 0x31C
F3.29
A02FM frequency
output lower limit
0.00k-50.00kHz 0.20kHz
●
99 0x31D
F3.30
A02FM frequency
output upper limit
0.00k-50.00kHz
50.00
kHz
●
99 0x31E
Keyboard and display parameters
NO.
Function description
Range of settings and definition
Factory
setting
Attribute
Referenc
e page
Communicati
on add
F4.00
Parameter and key
lock selections
0: Unlock
1: Function parameter lock
2: Function parameter and key lock
(except for RUN/STOP/JOG)
3: All function parameter and key lock
0
●
100 0x400
F4.01 User
password
0-9999
0
●
100 0x401