AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
22
●
Auxiliary terminal output capacity
Terminal
Function definition
Max output
+10V
10V auxiliary power supply output,constitutes loop
with GND.
50mA
A01/A02
Analog monitor output, constitutes loop with GND.
As frequency,voltage signal, max
output 2mA
+24V
24V auxiliary power supply output,constitutes loop
with COM.
100mA
Y1/Y2
Collector open circuit output can set the
action-object by programme.
DC24V/50mA
TA/TB/TC
Passive connector output can set the action-object
by programme.
3A/240VAC
5A/30VDC
Chart 3-4
:
AC90 series inverter auxiliary terminals output capacity
●
Switch terminals connection function specification
Switch
terminal
Selectable
position
Picture example
Function
specification
J1
0.2--50kHz
frequency output
J2
0--20mA current
output
4--20mA current
output
J3
0--10V voltage
output
J4 J6
J4 connect
J6 connect
Out track selection
J4 J6 (with PG
card ) Inner
track selection J5
J7 (without PG
card)
J5 J7
J 5 connect
J 7 connect
Chart 3-5
:
AC90 series inverter switch terminal connection function specification