AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
140
LED“00”digit: Time unit
0: second
1: minute
2: hour
LED“000”digit: Power down save mode
0: no save
1: save
Decide whether save running state while power down. If save, define recover mode by
[FC.15]
LED “0000” digit.If need
continute the state before power off, this parameter should be set as 1.
LED“0000”digit: Start-up mode
0: Restart from the 1st step
1: Restart from the step where stop
2: Restart from the time when stop
Set restart mode while stop for some reasons (stop, fault, power off and so on).
Output frequency is limited by upper/lowest limitation. While frequency is lower then lowest limitation, it runs
as [F0.13] lowest limitation mode.
FC.16
PLC 1st step running time
Setting range: 0.0-6500.0(s/m/h)
Factory set: 10.0
FC.17
PLC 2nd step running time
Setting range: 0.0-6500.0(s/m/h)
Factory set: 10.0
FC.18
PLC 3rd step running time
Setting range: 0.0-6500.0(s/m/h)
Factory set: 10.0
FC.19
PLC 4th step running time
Setting range: 0.0-6500.0(s/m/h)
Factory set: 10.0
FC.20
PLC 5th step running time
Setting range: 0.0-6500.0(s/m/h)
Factory set: 10.0
FC.21
PLC 6th step running time
Setting range: 0.0-6500.0(s/m/h)
Factory set: 10.0
FC.22
PLC 7th step running time
Setting range: 0.0-6500.0(s/m/h)
Factory set: 10.0
FC.23
PLC 8th step running time
Setting range: 0.0-6500.0(s/m/h)
Factory set: 10.0