AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
98
12
Current roll
diameter
Corresponding to current
max diameter setting of
Min output corresponding
to 0 meter
Max output corresponding to
max diameter
13 VS2
input
Corresponding to current
VS2 input
Min output corresponding
to VS2 input lowest limit
Max output corresponding to
VS2 input upper limit
14
Time per roll
Corresponding to time from
empty to full roll
Min output corresponding
to 0s
Max output corresponding to
time from empty to full roll
15 Reserved
16 VS1
input
Corresponding to current
VS1 input
Min output corresponding
to VS1 input lowest limit
Max output corresponding to
VS1 input upper limit
17 VS2
input
Corresponding to current
VS2 input
Min output corresponding
to VS2 input lowest limit
Max output corresponding to
VS2 input upper limit
18 AS
input
Corresponding to current
AS input
Min output corresponding
to AS input lowest limit
Max output corresponding to
AS input upper limit
19 PUL
input Corresponding to current
PUL input
Min output corresponding
to PUL input lowest limit
Max output corresponding to
PUL input upper limit
F3.24
A01 output gain
Setting range: 25.0-200.0%
Factory set: 100.0%
F3.25
A01 output signal bias
Setting range: -10.0-10.0%
Factory set: 0.0%
A01 output gain:
It is used for adjust AO1 terminal output analog.
A01 output signal bias:
It is used for adjust AO1 terminal 0 point of output signal.