![Veichi AC90 Скачать руководство пользователя страница 170](http://html1.mh-extra.com/html/veichi/ac90/ac90_manual_3940545170.webp)
AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
165
F8.24
ASR(VF) integral time 2
0.01-10.00s
0.50s
●
116 0x818
F8.25
ASR(VF) filter time 2
0.000-10.000s
0.100s
●
116 0x819
F8.26
ASR(VF) switch
frequency 2
0.00-50.00Hz 10.00Hz
●
116 0x81A
F8.27
ASR(VF) slip limit 0.0-500.0%
100.0%
●
117 0x81B
Tension control special parameters
NO
Function description
Range of settings and definition
Factory
setting
Attribute
Reference
page
Communica
tion add
F9.00
Tension setting selection
LED “0” digit: main channel selection
0: Keyboard No give
1: Keyboard pot give or modify
2: VS1 give or modify
3: VS2 give or modify
4: AS give or modify
5: PUL give or modify
6:RS485 give
LED “00” digit: Second channel
selection
0: Keyboard give
1: Keyboard pot give or modify
2: VS1 give or modify
3: VS2 give or modify
4: AS give or modify
5: PUL give or modify
6:RS485 give
LED “000” digit: Main channel
combines second channel
0: Main
×
[F9.01]
1: Second
×
[F9.02]
2: Main
×
[F9.01]
+
second
×
[F9.02]
3: Main
×
[F9.01]
-
second
×
[F9.02]
4: MAX{ Main
×
[F9.01],second
×
[F9.02]}
5: MIN{ Main
×
[F9.01],second
×
[F9.02]}
LED “000” digit: Reserved
0000
●
117 0x900
F9.01
Tension give main
channel gain
0-500.0%
100.0%
●
118 0x901
F9.02
Tension give second
channel gain
0-500.0%
100.0%
●
118 0x902
F9.03
Tension No setting
0-30000N
0
●
118 0x903