![Veichi AC90 Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/veichi/ac90/ac90_manual_3940545151.webp)
AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
146
F0.07
Frequency given
channels
combination mode
LED“0”digit:
0: Main channel valid
1: Auxiliary channel valid
2: Main + auxiliary
3: Main-auxiliary
4: MAX{ main, auxiliary }
5: MIN{ main, auxiliary }
6: Main*auxiliary
LED“10”digit:
0: Direction of frequency control is invalid
1: Direction of frequency control is invalid
LED“100”digit: Reserved
LED“1000”digit: Reserved
0000
〇
76 0x007
F0.08
Keyboard number
setting frequency
0-upper limit
50.00
Hz
●
77 0x008
F0.09
Max frequency
output
0-320.00Hz
50.00
Hz
〇
77 0x009
F0.10
Upper limitation
source selection
0: Upper limit frequency digital given
1: Keyboard potentiometer given
2 : Terminal VS1 voltage analog given
3: Terminal VS2 voltage analog given
4: Terminal AS current analog given
5: Terminal pulse signal
6: RS485 communication given
0
〇
77 0x00A
F0.11
Upper limit
frequency digital
setting
Lower limit-max output frequency
50.00
Hz
〇
77 0x00B
F0.12
low limit frequency
0-upper limit
0.00
〇
77 0x00C
F0.13
low limit frequency
running mode
0: Stop
1: Run as lower frequency limitation
1
〇
77 0x00D
F0.14
ACC time 1
0.01-650.00s
Accord
model
●
78 0x00E
F0.15
DEC time 1
0.01-650.00s
Accord
model
●
78 0x00F
F0.16 Rotate
direction
0: Consistent
1: Reverse
2: Reverse banned
0
●
79 0x010
F0.17 Carrier
frequency 0.6-15.0kHz
Accord
model
●
79 0x011