AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
154
F2.38
Over load per alarm
delay
0.0-100.0s 0.5s
●
95 0x226
F2.39
Under load pre alarm
level
0.0-200.0% 30.0%
●
95 0x227
F2.40
Under load pre alarm
delay
0.0-100.0s 0.5s
●
95 0x228
Modulus terminal functions
NO.
Function description
Range of settings and definition
Factory
setting
Attribute
Reference
page
Communicati
on add
F3.00
VS1 Lowest limit
0.00V-10.00V
0.00V
●
96 0x300
F3.01
VS1 Lowest limit
corresponding setting
0.00-100.00% 0.00%
●
96
0x301
F3.02
VS1 upper limit
0.00V-10.00V
10.00V
●
96
0x302
F3.03
VS1 upper limit
corresponding setting
0.00-100.00% 100.00%
●
96
0x303
F3.04
VS1 filter time
0.00s-10.00s
0.10s
●
96
0x304
F3.05
VS2 Lowest limit
0.00V-10.00V
0.00V
●
96
0x305
F3.06
VS2 Lowest limit
corresponding setting
0.00-100.00% 0.00%
●
96
0x306
F3.07
VS2 upper limit
0.00V-10.00V
10.00V
●
96
0x307
F3.08
VS2 upper limit
corresponding setting
0.00-100.00% 100.00%
●
97
0x308
F3.09
VS2 filter time
0.00s-10.00s
0.10s
●
97
0x309
F3.10
AS Lowest limit
0.00-20.00mA
4.00mA
●
97
0x30A
F3.11
AS Lowest limit
corresponding setting
0.00-100.00% 0.00%
●
97
0x30B
F3.12
AS upper limit
0.00-20.00mA
20.00mA
●
97
0x30C
F3.13
AS upper limit
corresponding setting
0-100.00% 100.00%
●
97
0x30D
F3.14
AS filter time
0.00s-10.00s
0.10s
●
97
0x30E
F3.15 Reserved
〇
97
0x30F
F3.16 Reserved
〇
97
0x310
F3.17 Reserved
〇
97
0x311
F3.18 Reserved
〇
97
0x312
F3.19 Reserved
〇
97
0x313
F3.20 Reserved
〇
97 0x314
F3.21 Reserved
〇
97 0x315