![Veichi AC90 Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/veichi/ac90/ac90_manual_3940545135.webp)
AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
130
state 0:
REV
1: REV
LED “00” digit: run state
0:stop
1:stable speed
2:ACC
3:DEC
LED “000” digit: reserved
LED “0000” digit: reserved
FA.32
Malfunction input terminal
state
See input terminal chart
--
FA.33
Malfunction output
terminal state
See input terminal chart
--
FA.34
The last 1 malfunction
types
Please see malfunction code table
--
FA.35
The last 1 malfunction
running frequency
0.00-max frequency
--
FA.36
The last 1 malfunction
output voltage
0-1500V --
FA.37
The last 1 malfunction
output current
0.1-2000.0A --
FA.38
The last 1 malfunction
bus voltage
0-3000V --
FA.39
The last 1 malfunction
module temperature
0-100
℃
--
FA.40
The last 1 machine state
LED “0” digit:run direction
0: REV
1: REV
LED “00” digit:run state
0:stop
1:stable speed
2:ACC
3:DEC
LED “000” digit:reserved
LED “0000” digit:reserved
--
FA.41
The last 1 malfunction
input terminal state
See input terminal chart
--
FA.42
The last 1 malfunction
output terminal state
See input terminal chart
--
FA.43
The last 2 malfunction
types
Please see malfunction code table
--
FA.44
The last 3 malfunction
types
Please see malfunction code table
--
Note: Malfunction records can be cleared by [F0.19]. See [F0.19] details.