AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
24
●
3-phase 380V machine main circuit wiring
Model
Main circuit terminals screw
specifications
Suggested fixed moment
(N·m)
Suggested Copper-core
cable specification mm
2
AC90-T3-R75T M4
1.2--1.5 1.5mm2(14)
AC90-T3-1R5T M4
1.2--1.5 2.5mm2(12)
AC90-T3-2R2T M4
1.2--1.5 2.5mm2(12)
AC90-T3-004T M4
1.2--1.5 4mm2(10)
AC90-T3-5R5T M4
1.2--1.5 6mm2(9)
AC90-T3-7R5T M5
2--2.5 6mm2(9)
AC90-T3-011T M5
2--2.5 10mm2(7)
AC90-T3-015T M6
4--6 10mm2(7)
AC90-T3-018T M6
4--6 16mm2(5)
AC90-T3-022T M8
8--10 16mm2(5)
AC90-T3-030T M8
8--10 25mm2(3)
AC90-T3-037T M8
8--10 25mm2(3)
AC90-T3-045T M8
8--10 35mm2(2)
AC90-T3-055T M10
11--13 35mm2(2)
AC90-T3-075T M10
11--13 50mm2(1)
AC90-T3-090T M10
11--13 50mm2(1/0)
AC90-T3-110T M10
11--13 70mm2(2/0)
AC90-T3-132T M10
11--13 95mm2(3/0)
AC90-T3-160T M12
14--16 95mm2(4/0)
AC90-T3-185T M12
14--16 120mm2
AC90-T3-200T M14
17--20 150mm2
AC90-T3-220T M14
17--20 150mm2
AC90-T3-250T M16
20--23 185mm2
AC90-T3-280T M16
20--23 185mm2
AC90-T3-315T M16
20--23 240mm2
AC90-T3-355T M16
20--23 240mm2
AC90-T3-400T M16
20--23 300mm2
AC90-T3-450T M16
20--23 400mm2
AC90-T3-500T M16
20--23 400mm2
AC90-T3-560T M16
20--23 500mm2
Note: Here we suggest to use copper joins as mains electric connectors of machine over 185KW. Pls refer the cut
section area above.
Chart 3-7: Suggested cable diameter and fixed moment 3-phase 380V machine main circuit