F9.04 Max
tension
0-30000N
0
●
118 0x904
F9.05 Tension
tape
coefficient 0.0-100.0%
0.0%
●
118 0x905
F9.06
Tape compensation
modify
0-10000mm
0
●
119 0x906
F9.07
Reserved
119
0x907
F9.08
Reserved
119
0x908
F9.09
Machine drive ratio
0.01-300.00
1.00
●
119 0x909
F9.10 Curl
mode
0: Winding (Roll diameter increase
gradually)
1: Unwinding (Roll diameter
decrease gradually)
0
●
119 0x90A
F9.11
Roll diameter calculation
selection
0:Initial roll diameter, no calculate
1:Line speed calculate
2:Calculate through the accumulative
thickness
3:Calculate through the time
4:Keyboard potentiometer give
winding roll diameter
5:VS1 give winding roll diameter
6:VS2 give winding roll diameter
7: AS give winding roll diameter
8: PUL give winding roll diameter
9:RS485 give winding roll diameter
0
●
120 0x90B
F9.12
Max roll diameter
1-10000mm
500
●
120 0x90C
F9.13 Reel
diameter
1-10000mm
100
●
120 0x90D
F9.14
Initial diameter resource
selection
0: Terminal select
1: Keyboard potentiometer
2:VS1
3:VS2
4:AS
5:PUL
0
●
120 0x90E
F9.15
Initial diameter 1
1-10000mm
100
●
121 0x90F
F9.16
Initial diameter 2
1-10000mm
100
●
121 0x910
F9.17
Initial diameter 3
1-10000mm
100
●
121 0x911
F9.18
Diameter reset selection
0: Manual reset 1: Auto reset
0
●
121 0x912
F9.19
Diameter filter time
0.1-100.0s
1.0s
●
121 0x913
F9.20
Current roll diameter
1-10000mm
*
●
121 0x914
F9.21
Roll diameter calculate
end frequency
0.00-50.00Hz
10.00
●
121 0x915
F9.22
Diameter reset delay
0-6000s
10
●
122 0x916