AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
160
F6.13
Constant power area
torque compensation
coefficient
0-100% 30%
●
106 0x60D
F6.14
Constant power area
limit start frequency
100.0%-500.0% 200.0%
●
106 0x60E
F6.15
Constant power area
limit value
50.0-200% 120%
●
106 0x60F
F6.16
DEC over-excitation
selection
0: off 1:on
0
●
106 0x610
F6.17
DEC over-excitation
current setting
50.0-200.0% 115.0%
●
106 0x611
F6.18
DEC over-excitation
gain
0.00-1.50
Accord
model
●
106 0x612
Torque control parameter
NO.
Function description
Range of settings and definition
Factory
setting
Attribute
Referenc
e page
Communic
ation add
F7.00
Torque give source
selection
LED “0” digit: Main channel selection
0:Keyboard number given torque
1:Keyboard potentiometer given
2: VS1
3: VS2
4: AS
5: PUL
6: RS485 communication give
7: Tension control give
LED “00” digit: Second channel
selection
0:Keyboard number given torque
1:Keyboard potentiometer given
2: VS1
3: VS2
4: AS
5: PUL
6: RS485 communication give
7: Tension control give
LED “000” digit: Main channel add
second channel mode
0: Main
×
[F7.02]
1: Second
×
[F7.03]
2: Main
×
[F7.02]+Second
×
[F7.03]
3: Main
×
[F7.02]
-
Second
×
[F7.03]
4:MAX{main
×
[F7.02], second
×
[F7.03]}
5:MIN {main
×
[F7.02],second
×
[F7.03]}
LED “0000” digit: Reserved
0000
〇
107 0x700
F7.01
Keyboard number
give torque
0-200.0%
100.0%
●
107 0x701
F7.02
Main torque give
channel gain
0-500.0%
100.0%
●
108 0x702