AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
124
6: RS485 gives and modifies the material thickness.
F9.40
Material thickness 1
Setting range:0.01-100.00mm
Factory set:0.01mm
F9.41
Material thickness 2
Setting range:0.01-100.00mm
Factory set:0.01mm
While Material thickness set resource
[
F9.39
]
is “0”,It can select “material thickness selection terminal” to define any
terminals. Details see
[
F2.00-F2.07
]
Set thickness by terminal switch can bring two group traction linear speed.
Relationship table as below:
Material thickness selection terminal
Material thickness
OFF
Material thickness 1
ON
Material thickness 2
F9.42 Reserved
F9.43 Reserved
Time calculate:
F9.44
Full roll diameter 1
Setting range:1-10000mm
Factory set:500
F9.45
Full roll diameter 2
Setting range:1-10000mm
Factory set:500
While roll diameter calculation selection
[F9.11]
is 3,
[F9.44-F9.48]
are valid. It can set full roll diameter by terminal
switch.It can select “full roll diameter selection terminal” to define any terminals. Details see
[F2.00-F2.07]
Set full roll
diameter by terminal switch can bring two group full roll diameter. Relationship table as below:
Full roll diameter selection
Full roll diameter
OFF
Full roll diameter 1
ON
Full roll diameter 2
F9.46
Empty to full roll time 1
Setting range:0-65000s
Factory set:3600
F9.47
Empty to full roll time 2
Setting range:0-65000s
Factory set:7200
It sets the time from empty roll to full roll. It can set empty to full roll time by terminal switch.It can select “empty to full
roll time selection terminal” to define any terminals. Details see
[F2.00-F2.07]
. Set empty to full roll time by terminal
switch can bring two groups empty to full roll time. Relationship table as below:
Empty to full roll time selection
Empty to full roll time
OFF
Empty to full roll time 1
ON
Empty to full roll time 2
F9.48
Current time
Refer range:0-65000s
Factory set:
*
It is used to monitor winding run time in real time.
F9.49-F9.51 Reserved