![Veichi AC90 Скачать руководство пользователя страница 136](http://html1.mh-extra.com/html/veichi/ac90/ac90_manual_3940545136.webp)
AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
131
9.12 Machine malfunction code table
Communic
ation code
Malfunction
code
Malfunction
LED code
Malfunction name
0 -- --
No
fault
1 L.U.1
Under-voltage at stop
2 E.LU2
Under-voltage while running
3 E.oU1
Over-voltage while ADD
4 E.oU2
Over-voltage while DEC
5 E.oU3
Over-voltage at constant speed
6 E.oU4
Over-voltage at stop
7 E.oC1
Over-current while ADD
8 E.oC2
Over-current while DEC
9 E.oC3
Over-current at constant speed
10 E.oL1
Motor overload
11 E.oL2
Frequency inverter overload
12 E.
SC
System abnormal
13 E.oH1
Inverter overheat
14 E.oH2
Rectifier bridge overheat
15 E.tE1
Motor detect malfunction at static state
16 E.tE2
Motor detect malfunction circularly
17 E.EEP
Store malfunction
18 L
IFE
Reserved
19 E.ILF
Input side phase lack
20 E.oLF
Output side phase lack
21 E.GnD
Output earth
22 E.HAL
Current detection fault
23 E.
EF
Exterior fault
24 E.PAn
Keyboard connection fault
25 E.
CE
Rs485 communication fault
26 E.CPE
Parameter copy fault
27 E.ECF
Optional card connection fault
28 E.
PG
PG card connection fault
29 E.PID
PID feedback wire connection fault
30 E.EDI
Copoy software not compatible