![Veichi AC90 Скачать руководство пользователя страница 161](http://html1.mh-extra.com/html/veichi/ac90/ac90_manual_3940545161.webp)
AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
156
F4.02 REV/JOG
selections
0: REV
1: JOG
0
●
100 0x402
F4.03
STOP key function
range
LED “0”digit: terminal control
0: invalid to terminal order
1: valid to terminal order
LED“00”digit: communication control
0: invalid to communication order
1: valid to communication order
LED “000” digit: reserved
LED “0000” digit: reserved
0000
●
100 0x403
F4.04
UP/DOWN key
modification
selections
LED “0” digit: keyboard UN/DOWN key
modify selection
0: Invalid
1: Modify frequency setting by key
board numbers
(
F0.08
)
2: Reserved
3: Modify PID give setting by key
board numbers
(
Fb.01
)
4: Reserved
LED “00” digit: keyboard UN/DOWN
key store selection
0: No save after power down
1: Save after power down
LED “000” digit: reserved
LED “0000” digit: reserved
0011
●
101 0x404
F4.05
Function parameter
copy
0: No operation
1: Send machine parameters to
keyboard and save
2: Send parameters to keyboard and
save
0
〇
101 0x405
F4.06 Reserved
101
0x406
F4.07
Keyboard
potentiometer lowest
limit
0.00V-5.00V 0.50V
●
101 0x407
F4.08
Keyboard
potentiometer lowest
limit corresponding
setting
0-100.00% 0.00%
●
101 0x408
F4.09
Keyboard
potentiometer upper
limit
0.00V-5.00V 4.50V
●
101 0x409
F4.10
Keyboard
potentiometer upper
limit corresponding
setting
0-100.00% 100.00%
●
101 0x40A