AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
96
9.4 Analog terminal functions
F3.00
VS1 Lowest limit
Setting range: 0.00-10.00V
Factory set: 0.00V
F3.01
VS1 Lowest limit
corresponding setting
Setting range: 0.00-100.00%
Factory set: 0.00%
F3.02
VS1 upper limit
Setting range: 0.00-10.00V
Factory set: 10.00V
F3.03
VS1 upper limit
corresponding setting
Setting range: 0.00-100.00%
Factory set: 100.00%
F3.04
VS1 filter time
Setting range: 0.00-10.00s
Factory set: 0.10s
VS1 Lowest limit:
It defines signal accepted by analog input terminal
(VS1)
, Inverter deal voltage lower than this value
as lower limit.
VS1 lower limit corresponding setting:
It defines ratio of VS1 lower limit.
VS1 upper limit:
It defines signal accepted by analog input terminal
(VS1)
, Inverter deal voltage higher than this value
as higher limit.
VS1 upper limit corresponding setting:
It defines ratio of VS1 upper limit.
VS1 filter time:
It is
(VS1)
input analog signal filter time to eliminate disturb signal. The longer filter time is, the stronger
anti-disturb force is. The shorter filter time is, the weaker anti-disturb force is. But respond speed will be quicker.
give frequency
F0.09
×
F3.03
F0.09
×
F3.01
F3.00
F3.02 Input voltage
give frequency
F0.09
×
F3.03
Input voltage
F3.02
F3.00
F0.09
×
F3.01
Anaiog give frequency show
Analog give torque and tension, the relationship:
Give torque
200% torque
Input voltage
F3.02
F3.00
F7.07
Input torque
lower limit
F7.06
Input torque
upper limit
Give tension
F9.04 Max
tension
F3.00
F3.02
Input voltage
VS1 analog give torque/tension figure
F3.05
VS2 Lowest limit
Setting range: 0.00-10.00V
Factory set: 0.00V
F3.06
VS2 Lowest limit
corresponding setting
Setting range: 0.00-100.00%
Factory set: 0.00%
F3.07
VS2 upper limit
Setting range: 0.00-10.00V
Factory set: 10.00V