AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
176
FC.45
PLC 15
th
step
direction and
ADD/DEC time
0000
●
141 0xC2D
FC.46 Reserved
141
0xC2E
FC.47 Reserved
141
0xC2F
FC.48
Swing frequency
control
LED “0” digit: swing frequency control
0: invalid
1:valid
LED “00” digit: swing frequency get in
mode
0: Automatic
1: manual
LED “000” digit: AW control
0: variable
1: fixed
LED “0000” digit: reserved
0000
〇
141 0xC30
FC.49
Swing frequency
pre-set
0.0-max frequency
0.00Hz
●
141 0xC31
FC.50
Pre-set frequency
hold time
0.00-650.00s 0.00s
●
141 0xC32
FC.51
Swing frequency
range
0.0-100.0% 0.0%
●
141 0xC33
FC.52
Jumping frequency
amplitude
0.0-50.0% 0.0%
●
141 0xC34
FC.53
Swing frequency ACC
time
0.00-650.00s 5.00s
●
142 0xC35
FC.54
Swing frequency DEC
time
0.00-650.00s 5.00s
●
142 0xC36
Communication control function parameters
NO.
Function description
Range of settings and definition
Factory
setting
Attribute
Reference
page
Communic
ation add
Fd.00
Main-slave machine
selection
0: Main machine
1: Slave machine
0
〇
143 0xD00
Fd.01 Machine
add
1-247
1
〇
143 0xD01
Fd.02
Communication baud
rate selection
0: 1200 bps
1: 2400 bps
2: 4800 bps
3: 9600 bps
4: 19200 bps
5: 38400 bps
3
〇
143 0xD02
Fd.03 Data
format
0: (N,8,1) no checkout,
Data digit: 8,
Stop digit: 1
0
〇
143 0xD03