AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
103
9.6 Motor parameters
F5.00 Reserved
F5.01
Motor rate
Setting range: 2-48
Factory set: 4
Set it according to nameplate.
F5.02
Motor rated power
Setting range: 0.4-1000.0kW
Factory set: Accord model
Set it according to nameplate based on unit of 0.1kw. While motor rated power setting is changed, inverter will
automatic adjust
[F5.03-F5.11]
to default. If self-study,
[F5.07-F5.11]
will automatic change according to the result of
self study. If need high accuracy control, It must self study after right
[F5.01-F5.06]
setting.
F5.03 Motor
rated
frequency
Setting range: 0.01Hz-max frequency
Factory set: Accord model
Set it according to nameplate.
F5.04
Motor rated speed
Setting range: 0-65000rpm Factory
set: Accord model
Set it according to nameplate.
F5.05
Motor rated voltage
Setting range: 0-1500V Factory
set: Accord model
Set it according to nameplate.
F5.06
Motor rated current
Setting range: 0.1-2000.0A Factory
set: Accord model
Set it according to nameplate.
F5.07
Motor no-load current
Setting range: 0.01-650.00A
Factory set: Accord model
It set automatic while self study.
F5.08
Motor stator resistance
Setting range: 0.001-65.000
Factory set: Accord model
It set automatic while self study.
F5.09
Motor rotor resistance
Setting range: 0.001-65.000
Factory set: Accord model
It set automatic while self study.
F5.10
Motor stator&rotor
inductance
Setting range: 0.1-6500.0mH
Factory set: Accord model
It set automatic while self study.
F5.11
Motor stator&rotor mutual
inductance
Setting range: 0.1-6500.0mH
Factory set: Accord model
It set automatic while self study.
F5.12
Parameters self-adjustment
selections
Setting range: 0-2
Factory set: 0