AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Function Parameter specifications
89
39: Frequency channel switch terminal 4
It is valid only when
[F0.03]
is set as 12. Main frequency input channel is selected by terminal. 4 terminals can be
combined to 0-11 which is corresponding to frequency input channels 0-11 of
[F0.03]
. Details refer to
[F0.03]
.
40: Timer touch terminal
Closed is valid.Detail refer to
[F2.25-F2.26]
.
41: Timer clear terminal
Closed is valid.Detail refer to
[F2.25-F2.26]
.
42: Counter clock input terminal
Detail refer to
[F2.27-F2.28]
.
43: Counter clear terminal
Closed is valid.Detail refer to
[F2.27-F2.28]
.
44: DC brake order
At stop state, it can start DC brake function.Details refer to
[F1.09]
. If input run order or JOG order,
DC braking will be stopped.
45: Pre-excitation order terminal
At stop state, it can start pre-excitation function. If input run order or JOG order,
pre-excitation order is cancelled.
46: Reserved
47: Start magnetic particle clutch function
While it is valid, the inverter will start the magnetic particle clutch function.
Details see
[
F7.14-F7.17
]
48: PID parameter switch terminal 1
49: PID parameter switch terminal 2
50: Initial roll diameter setting terminal 1
Two different terminals combination corresponds to different initial roll
diameter only when parameter
[
F9.14
]
is set as “0”(terminal selection) in diameter calculation. Details see
[F9.15-F9.17]
.
51: Initial roll diameter setting terminal 2
Two different terminals combination corresponds to different initial roll
diameter only when parameter
[
F9.14
]
is set as “0”(terminal selection) in diameter calculation. Details see
[F9.15-F9.17].
52: Linear speed selection terminal
It is valid only when parameter
[
F9.14
]
is set as “1”(calculate by linear speed)
in diameter calculation. This terminal can make the switch between linear speeds setting 1 and linear speed setting 2
coming ture. Details see
[F9.28-F9.29]
.
53
:
Material thickness selection terminal
It is valid only when parameter
[
F9.14
]
is set as “2”(calculate by
thickness) in diameter calculation. This terminal can make the switch between material thickness 1 and material
thickness 2 coming ture. Details see
[F9.40-F9.41]
.
54
:
Full roll diameter selection terminal
It is valid only when parameter
[
F9.14
]
is set as “3”(calculate by time)
in diameter calculation. This terminal can make the switch between empty roll to full roll time 1 and full roll to empty roll
time 2 coming ture. Details see
[F9.44-F9.45]
.
55
:
Empty to full roll time selection terminal
It is valid only when parameter
[
F9.14
]
is set as “3”(calculate by time)
in diameter calculation. This terminal can make the switch between empty roll to full roll time 1 and full roll to empty roll