AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL BASIC OPERATION AND TRIAL RUN
152
F2.13
Terminal action
mode
LED “0” digit: free stop terminal reset
mode
0: Reset to original order while invalid
1: Not reset to original order while invalid
LED “00” digit: emergency stop terminal
reset mode
0: Reset to original order while
disconnect
1: Not reset to original order while
disconnect
LED “000” digit: terminal run mode after
fault reset
0: Terminal control to power on
directly
1: Terminal control to power on after stop
LED “0000” digit: reserved
0111
●
91 0x20D
F2.14 Reserved
92
0x20E
F2.15 Reserved
92
0x20F
F2.16
PUL input min
frequency
0.0-50.00kHz 0.00kHz
●
92
0x210
F2.17
PUL min frequency
corresponding
setting
0.00-100.00% 0.00%
●
92
0x211
F2.18
PUL input max
frequency
0.0-50.00kHz
50.00
kHz
●
92
0x212
F2.19
PUL max frequency
corresponding
setting
0-100.00% 100.00%
●
92
0x213
F2.20
PUL filter time
0.00s-10.00s
0.10s
●
92
0x214
F2.21
PUL cut-off
frequency
0.000-50.000kHz
0.010
kHz
●
92
0x215
F2.22
UP/DW terminal
frequency adjust
selection
0:Off electricity storage
1:Off electricity does not storage
2:Valid in running, clear zero at stop
0
●
92
0x216
F2.23
UP/DW terminal
frequency add/dec
speed time
0.01-50.00Hz/s 0.50Hz/s
●
92
0x217
F2.24 Reserved
93
0x218
F2.25
Timer time of unit
0: Second
1: Minute
2: Hour
0
●
93
0x219
F2.26 Timer
setting
0-65000
0
●
93
0x21A
F2.27
Counter max value
0-65000
1000
●
93
0x21B