F5.15 PG
selection
LED “0” digit:
0: 1-phasee input
1: 2-phase input
LED “00” digit:
0: same direction
1: reverse direction
LED “000” digit:
0: break inspection OFF
1: break inspection ON
LED“0000”digit:PG feedback channel
0: PG port
0001
〇
104 0x510
F5.16
Number of pulses per
circle
0-60000 1024
〇
104
0x511
F5.17
PG break line
inspection time
0.100-60.000s 2.000s
●
104
0x512
VC control parameter
NO.
Function description
Range of settings and definition
Factory
setting
Attribute
Referen
ce page
Communicati
on add
F6.00
ASR proportional
gain 1
0.00-1.00
Accord
model
●
105 0x600
F6.01
ASR integral time 1
0.01-10.00s
Accord
model
●
105 0x601
F6.02
ASR differential time
1
0.0-100.0 0.0
●
105 0x602
F6.03
ASR filter time1
0.000-0.100s
0.005s
●
105 0x603
F6.04
ASR switch
frequency 1
0.0Hz-50.0Hz 5.00Hz
●
105 0x604
F6.05
ASR proportional
gain 2
0.00-1.00
Accord
model
●
105 0x605
F6.06
ASR integral time 2
0.01-10.00s
Accord
model
●
105 0x606
F6.07
ASR differential time
2
0.0-100.0 s
0.0s
●
105 0x607
F6.08
ASR filter time 2
0.000-0.100s
0.001
●
105 0x608
F6.09
ASR switch
frequency 2
0.00-50.00Hz 10.0Hz
●
105 0x609
F6.10
VC slip coefficient
10-250%
100%
●
105 0x60A
F6.11 Max
output
torque 20.0-200.0%
180.0%
●
106 0x60B
F6.12
Constant power area
torque compensation
start frequency
100.0%-500.0% 120.0%
●
106 0x60C