Monobloc Outdoor Unit Service Manual
12
Full Load Performance*
RUA-CP1701H
RUA-CP2101H
Nominal heating capacity (EWT 30°C / LWT 35°C & OAT 7°C) ~
kW
H1
17.1
21.1
COP ~ W/W
H1
4.1
4.1
Eurovent class heating
H1
A
A
Nominal heating capacity (EWT 40°C / LWT 45°C & OAT 7°C) ~
kW
H2
16.2
20.0
COP ~ W/W
H2
3.4
3.3
Eurovent class heating
H2
A
A
Nominal heating capacity (EWT 50°C / LWT 55°C & OAT 7°C) ~
kW
H3
15.3
19.1
COP ~ W/W
H3
2.7
2.7
Heating Leaving water temperature range (min ~ max) °C
20 ~ 60
20 ~ 57
Nominal cooling capacity (EWT 12°C / LWT 7°C & OAT 35°C) ~
kW
C1
14.9
18.6
EER ~ W/W
C1
3.0
3.1
Eurovent class cooling
C1
B
A
Nominal cooling capacity (EWT 23°C / LWT 18°C & OAT 35°C) ~
kW
C2
19.8
25.8
EER ~ W/W
C2
3.9
3.8
Eurovent class cooling
C2
A
A
Cooling Leaving water temperature range (min ~ max) °C
5 ~ 18
5 ~ 18
Notes:
* = in accordance with EN14511-3:2013
C1 = cooling mode conditions: evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C
C2= cooling mode conditions: evaporator water entering/leaving temperature 23°C/18°C, outside air temperature 35°C
H1= heating mode conditions: water heat exchanger entering/leaving temperature 30°C/35°C. Outside air temperature
7°CDB/6°CWB
H2= heating mode conditions: water heat exchanger entering/leaving temperature 40°C/45°C. Outside air temperature
7°CDB/6°CWB
H3= heating mode conditions: water heat exchanger entering/leaving temperature 47°C/55°C. Outside air temperature
7°CDB/6°CWB
(1) Values are guidelines only. Refer to unit nameplate
(2) In dB ref=10-12W, (A) weighting. Declared dual number noise emission values in accordance with ISO 4871
(3) In dB ref 20
μPa, (A) weighting. Declared dual number noise emission values in accordance with
ISO 4871
(4) Minimum water-side operating pressure with fixed speed pump is 50kPa and with variable speed pump is 40kPa
Electrical data
RUA-CP****H* – Full Options
RUA-CP1701H
RUA-CP2101H
Power circuit
Nominal power supply ~ V/ph/Hz
400 / 3+N / 50
Voltage range ~ V
360 - 440
Control circuit supply
24V AC internal transformer
Nominal current at nominal voltage (Un)
1
~ (A)
12.5
14.3
Maximum power input at nominal voltage (Un)
2
~ kW
10.8
12.4
Power factor at maximum power
2
~
Φ
0.93
Maximum current at nominal voltage – 10% (Un-10%)
3
~ A
18.5
21.2
Maximum unit current (Un)
4
~ A
16.7
19.1
Maximum start up current – standard unit
5
~ A
Not applicable
(less than the operating current)
Note:
1 = Conditions equivalent to the standardised Eurovent conditions (evaporator water entering-leaving temperature = 12 °C/7 °C,
outside air temperature = 35 °C)
2 = Power input, compressors and fans, at the unit operating limits (saturated suction temperature 15 °C, saturated condensing
temperature 68.3 °C) and nominal voltage of 400 V (data given on the unit nameplate)
3 = Maximum unit operating current at maximum unit power input and at 360 V
4 = Maximum unit operating current at maximum unit power input and at 400 V (values given on the unit nameplate)
5 = Maximum instantaneous start-up current at operating limits (maximum operating current of the smallest compressor(s) + fan
c locked rotor current of the largest compressor).
Содержание Estia RUA-CP1701H
Страница 15: ...Monobloc Outdoor Unit Service Manual 14 4 3 ESTIA hot water cylinder ...
Страница 18: ...Monobloc Outdoor Unit Service Manual 17 5 1 3 Wiring Diagram Sheet 6 ...
Страница 19: ...Monobloc Outdoor Unit Service Manual 18 5 1 4 Wiring Diagram Sheet 7 ...
Страница 20: ...Monobloc Outdoor Unit Service Manual 19 5 1 5 Wiring Diagram Sheet 8 ...
Страница 21: ...Monobloc Outdoor Unit Service Manual 20 5 2 General electrical connection 5 3 ESTIA hot water cylinder ...
Страница 24: ...Monobloc Outdoor Unit Service Manual 23 6 3 3 MCC 1599 interface PCB 6 3 4 MCC 1600 noise filter ...
Страница 28: ...Monobloc Outdoor Unit Service Manual 27 7 2 Refrigeration cycle system diagram Pumpless models ...
Страница 29: ...Monobloc Outdoor Unit Service Manual 28 Variable fixed speed hydraulic models ...
Страница 70: ...Monobloc Outdoor Unit Service Manual 69 ...
Страница 75: ...Monobloc Outdoor Unit Service Manual 74 ...
Страница 157: ...Monobloc Outdoor Unit Service Manual 156 16 2 21kW Fixed Speed Variable Speed Pumpless ...
Страница 160: ...Monobloc Outdoor Unit Service Manual 159 ...
Страница 161: ...Monobloc Outdoor Unit Service Manual 160 ...
Страница 162: ......
Страница 163: ......
Страница 164: ...TOSHIBA CARRIER EUROPE S A S Route de Thil 01120 Montluel France 1402410501R03 ...