Operation manual

Daikin Altherma 3 H HT ECH

O

English

Operation manual

Daikin Altherma 3 H HT ECH

O

ETSH16P30EF
ETSH16P50EF
ETSHB16P30EF
ETSHB16P50EF
ETSX16P30EF
ETSX16P50EF
ETSXB16P30EF
ETSXB16P50EF

Содержание ETSH16P50EF

Страница 1: ...Operation manual Daikin Altherma 3 H HT ECH O English Operation manual Daikin Altherma 3 H HT ECH O ETSH16P30EF ETSH16P50EF ETSHB16P30EF ETSHB16P50EF ETSX16P30EF ETSX16P50EF ETSXB16P30EF ETSXB16P50EF...

Страница 2: ...19 11 1 Configuration wizard 19 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure...

Страница 3: ...Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place...

Страница 4: ...the part from which the refrigerant leaked has been repaired WARNING Air purging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home...

Страница 5: ...F space heating cooling operation C 2 Operation Space heating cooling room frost protection operation if enabled can still activate However for leaving water temperature control and external room ther...

Страница 6: ...changes c Slope d Offset Possible actions on this screen Select slope or offset Increase or decrease the slope offset When slope is selected set slope and go to offset When offset is selected set offs...

Страница 7: ...can Update the software This requires a correct config file on the USB memory stick Import the settings generated by E Configurator Heating Solutions Navigator from the USB memory stick to the user in...

Страница 8: ...ar Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Mode Schedule Level 7 5 Electricity price High Medium Low Schedule 5 Tank Powerful operation Schedule 1 9 Room comf...

Страница 9: ...mp failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is curren...

Страница 10: ...ure 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving wa...

Страница 11: ...on OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OFF Space heating cooling operation NOTICE Room frost protection...

Страница 12: ...Space heating cooling Operation mode 2 Select one of the following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and co...

Страница 13: ...y With the higher set temperature in the afternoon and evening more hot water is available During the morning you consume hot water and the storage tank temperature decreases When the tank temperature...

Страница 14: ...the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delete Delete Rename Select 3 Select OK to confirm To clear the content of a day schedule 1 Select the day of whic...

Страница 15: ...Weather dependent curve 5 9 1 What is a weather dependent curve Weather dependent operation The unit operates weather dependent if the desired leaving water or tank temperature is determined automatic...

Страница 16: ...ambient temperatures For example if leaving water temperature is in general fine but at low ambient temperatures too cold raise the slope so that leaving water temperature is heated increasingly more...

Страница 17: ...e tank When the maximum or minimum setpoint is reached the curve flattens out To fine tune the weather dependent curve slope offset curve The following table describes how to fine tune the weather dep...

Страница 18: ...too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See 5 6 2 To change the desired room tempe...

Страница 19: ...d to purge air with the air purge function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air purging heat emitters or co...

Страница 20: ...installer Operation manual 20 ETSH X B 16P30 50EF Daikin Altherma 3 H HT ECH O 4P679469 1 2022 02 11 2 Settings menu Setting Fill in Main zone Thermostat type 2 A Additional zone if applicable Thermos...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...4P679469 1 2022 02 Copyright 2022 Daikin 4P679469 1 0000000 Verantwortung f r Energie und Umwelt...