background image

5 Operation

Operation manual

7

ETSH/X(B)16P30+50EF
Daikin Altherma 3 H HT ECH

O

4P679469-1 – 2022.02

2

Adjust the domestic hot water temperature.

+

50

°C

5

a

b

Tank

a

 Actual domestic hot water temperature

b

 Desired domestic hot water temperature

In other modes, you can only view the setpoint screen but not modify
it.

More information

For more information, see also:

"5.4 Turning operation ON or OFF"

 [

4

 11]

"5.7 Domestic hot water control"

 [

4

 13]

"5.8 Schedule screen: Example"

 [

4

 14]

▪ User reference guide

5

Operation

INFORMATION

Cooling is only applicable in case of reversible models.

5.1

User interface: Overview

The user interface has the following components:

a
b

c

a

Status indicator

b

LCD screen

c

Dials and buttons

Status indicator

The  LEDs  of  the  status  indicator  light  up  or  blink  to  show  the
operating mode of the unit.

LED

Mode

Description

Blinking blue

Standby

The unit is not in operation.

Continuous blue Operation

The unit is in operation.

Blinking red

Malfunction

A malfunction occurred.

See 

"8.1 To display the help text

in case of a malfunction"

 [

4

 18]

for more information.

Slot for WLAN cartridge

With the WLAN cartridge, the installer can connect the system to the
internet.  As  user  you  can  then  control  the  system  via  the  Daikin
Residential  Controller  app. 

Note: 

This  slot  cannot  be  used  for  SD

cards.

USB connector

With a USB memory stick, the installer can:

▪ Update the software. This requires a correct config file on the USB

memory stick.

▪ Import  the  settings  generated  by  E-Configurator  (Heating

Solutions  Navigator)  from  the  USB  memory  stick  to  the  user
interface  (MMI).  This  requires  a  correct  config  file  on  the  USB
memory stick.

▪ Export  the  current  settings  (i.e.  field  settings,  MMI  EEPROM

settings,  schedule  timers)  from  the  user  interface  (MMI)  to  the
USB memory stick.

LCD screen

The  LCD  screen  has  a  sleeping  function.  After  15  min  of  non-
interaction with the user interface, the screen darkens. Pressing any
button or rotating any dial awakens the display.

Dials and buttons

You use the dials and buttons:

▪ To navigate through the screens, menus and settings of the LCD

screen

▪ To set values

a

b

c

d

e

Item

Description

a

Left dial

The LCD shows an arc on the left side of the
display when you can use the left dial.

:  Turn,  then  press  the  left  dial.  Navigate

through the menu structure.

: Turn the left dial. Choose a menu item.

: Press the left dial. Confirm your choice

or go to a submenu.

b

Back button

: Press to go back 1 step in the menu structure.

c

Home
button

: Press to go back to the home screen.

d

Help button

: Press to show a help text related to the current

page (if available).

e

Right dial

The LCD shows an arc on the right side of the
display when you can use the right dial.

: Turn, then press the right dial. Change

a value or setting, shown at the right side of the
screen.

:  Turn  the  right  dial.  Navigate  through

the possible values and settings.

:  Press  the  right  dial.  Confirm  your

choice and go to the next menu item.

Содержание ETSH16P50EF

Страница 1: ...Operation manual Daikin Altherma 3 H HT ECH O English Operation manual Daikin Altherma 3 H HT ECH O ETSH16P30EF ETSH16P50EF ETSHB16P30EF ETSHB16P50EF ETSX16P30EF ETSX16P50EF ETSXB16P30EF ETSXB16P50EF...

Страница 2: ...19 11 1 Configuration wizard 19 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure...

Страница 3: ...Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do NOT place...

Страница 4: ...the part from which the refrigerant leaked has been repaired WARNING Air purging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home...

Страница 5: ...F space heating cooling operation C 2 Operation Space heating cooling room frost protection operation if enabled can still activate However for leaving water temperature control and external room ther...

Страница 6: ...changes c Slope d Offset Possible actions on this screen Select slope or offset Increase or decrease the slope offset When slope is selected set slope and go to offset When offset is selected set offs...

Страница 7: ...can Update the software This requires a correct config file on the USB memory stick Import the settings generated by E Configurator Heating Solutions Navigator from the USB memory stick to the user in...

Страница 8: ...ar Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Mode Schedule Level 7 5 Electricity price High Medium Low Schedule 5 Tank Powerful operation Schedule 1 9 Room comf...

Страница 9: ...mp failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is curren...

Страница 10: ...ure 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving wa...

Страница 11: ...on OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OFF Space heating cooling operation NOTICE Room frost protection...

Страница 12: ...Space heating cooling Operation mode 2 Select one of the following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and co...

Страница 13: ...y With the higher set temperature in the afternoon and evening more hot water is available During the morning you consume hot water and the storage tank temperature decreases When the tank temperature...

Страница 14: ...the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delete Delete Rename Select 3 Select OK to confirm To clear the content of a day schedule 1 Select the day of whic...

Страница 15: ...Weather dependent curve 5 9 1 What is a weather dependent curve Weather dependent operation The unit operates weather dependent if the desired leaving water or tank temperature is determined automatic...

Страница 16: ...ambient temperatures For example if leaving water temperature is in general fine but at low ambient temperatures too cold raise the slope so that leaving water temperature is heated increasingly more...

Страница 17: ...e tank When the maximum or minimum setpoint is reached the curve flattens out To fine tune the weather dependent curve slope offset curve The following table describes how to fine tune the weather dep...

Страница 18: ...too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See 5 6 2 To change the desired room tempe...

Страница 19: ...d to purge air with the air purge function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air purging heat emitters or co...

Страница 20: ...installer Operation manual 20 ETSH X B 16P30 50EF Daikin Altherma 3 H HT ECH O 4P679469 1 2022 02 11 2 Settings menu Setting Fill in Main zone Thermostat type 2 A Additional zone if applicable Thermos...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...4P679469 1 2022 02 Copyright 2022 Daikin 4P679469 1 0000000 Verantwortung f r Energie und Umwelt...

Отзывы: