Monobloc Outdoor Unit Service Manual
108
10.1.3.2. Status Table
Access type: Read-only (force is possible)
TABLE NAME: STATUS, PIC Table Type: 11H, instance 2
PAR.
NAME
RANGE
DEFAULT
UNIT
DESCRIPTION
41
CHIL_OCC
0 to 2
-
-
Occupancy Mode
1
42
sum_mode
No / Yes
No
-
Summer Mode
43
nightmod
No / Yes
No
-
Night Mode
44
MOD_REQ
0 to 9
-
-
System Mode Request
2
45
MOD_STAT
0 to 109
-
-
System Mode Status
3
47
mod_ovr
0 to 12
-
-
System Mode Override
4
48
setpoint
0.0 to 60.0
-
°C
Current Setpoint
5
49
RESET
-5.0 to 5.0
0.0
^C
User Adjust Temperature
6
50
IAT_OFF
-4.0 to 4.0
0.0
^C
IAT Offset
51
CTRL_PNT
0.0 to 60.0
-
°C
Water Control Point
52
CTRL_TMP
-40.0 to 115.6
-
°C
Water Control Temp
1. Occupancy mode
0 = Away
1 = Sleep
2 = Home
2. System mode request
0 = Off
1 = Cool
2 = Heat
3 = unused
4 = DHW
5 = Booster Cooling
6 = Booster Heating
7 = unused
8 = Purge (water pump is constantly running to purge the
hydraulic circuit)
9 = Drying (slow water temp. ramp-up in Heating mode
for UFH drying)
3. System mode status (read-only)
0 = Off
1 = Cool
2 = Heat
3 = unused
4 = DHW (Heat)
5 = Booster Cooling
6 = Booster Heating
7 = Defrost
8 = Purge
9 = Drying
20 = Home Anti-Freeze
21 = Cool Satisfied
22 = Heat Satisfied
24 = DHW Satisfied
29 = Drying Satisfied
100 = Off Fail
101 = Cool Fail
102 = Heat Fail
104 = DHW Fail
105 = B. Cool Fail
106 = B. Heat Fail
107 = Defrost Fail
108 = Purge Fail
109 = Drying Fail
4. System mode override
0 = No override
1 = Home anti-freeze protection
2 = Water anti-freeze protection
10 = Load shedding request
(Unit not allowed to run)
11 = Off-peak is active
(Electric Heaters not allowed)
12 = Solar Mode is active
(Heat Mode and DHW Mode not allowed)
In case of power cycle, the previous System Mode
Request and the previous Occupancy Mode will be
automatically selected.
5. Current setpoint
Depending on WUI configuration, the parameter
corresponds to either Water or Air temperature.
WUI type
IAT as
Thermostat
Current
Setpoint
None
-
Water
Contacts
No
Air
Yes
Air
Local
-
Water
Remote
No
Air
Yes
Air
6. User adjust temperature
This temperature can be reset only via Network or JBus.
Содержание Estia RUA-CP1701H
Страница 15: ...Monobloc Outdoor Unit Service Manual 14 4 3 ESTIA hot water cylinder ...
Страница 18: ...Monobloc Outdoor Unit Service Manual 17 5 1 3 Wiring Diagram Sheet 6 ...
Страница 19: ...Monobloc Outdoor Unit Service Manual 18 5 1 4 Wiring Diagram Sheet 7 ...
Страница 20: ...Monobloc Outdoor Unit Service Manual 19 5 1 5 Wiring Diagram Sheet 8 ...
Страница 21: ...Monobloc Outdoor Unit Service Manual 20 5 2 General electrical connection 5 3 ESTIA hot water cylinder ...
Страница 24: ...Monobloc Outdoor Unit Service Manual 23 6 3 3 MCC 1599 interface PCB 6 3 4 MCC 1600 noise filter ...
Страница 28: ...Monobloc Outdoor Unit Service Manual 27 7 2 Refrigeration cycle system diagram Pumpless models ...
Страница 29: ...Monobloc Outdoor Unit Service Manual 28 Variable fixed speed hydraulic models ...
Страница 70: ...Monobloc Outdoor Unit Service Manual 69 ...
Страница 75: ...Monobloc Outdoor Unit Service Manual 74 ...
Страница 157: ...Monobloc Outdoor Unit Service Manual 156 16 2 21kW Fixed Speed Variable Speed Pumpless ...
Страница 160: ...Monobloc Outdoor Unit Service Manual 159 ...
Страница 161: ...Monobloc Outdoor Unit Service Manual 160 ...
Страница 162: ......
Страница 163: ......
Страница 164: ...TOSHIBA CARRIER EUROPE S A S Route de Thil 01120 Montluel France 1402410501R03 ...