8.4. Inverter Control logic
8.4.1. Compressor short cycling protection
For reliability purposes when the compressor goes from On to Off, it must remain off for at least of 2
minutes 30 seconds (minimum off time). And to avoid short and frequent on / off cycles, the control
algorithm will wait 3 minutes (maximum on time) before stop the unit.
8.4.2. Minimum compressor run time
For reliability purposes this algorithm forces the compressor to run for a minimum amount of time. Once the
compressor is running, it must run for a minimum of 3 minutes before switching off.
This protection is ignored when:
•
An alarm forces the compressor off
•
User requests the unit to turn off
•
A/C Power Interruption
•
A mode change occurs
•
20 second loss of high voltage communications
8.4.3. Two-way Valve Control
The conditions for opening and closing the 2-way valve are shown in the table below.
2-way valve “Open” Conditions
2-way valve “Close” Condtions
Non-operation
(1)
When operation stopped after
operating
When operation started after
operating or when 30 minutes
elapsed after opening 2-way valve
under conditions (1) (2)
(2) When power placed “ON”
During Cooling
Operations
(3)
When 30 second elapses after first
startup operation when power ON at
TO ≤ 5° C
When 8 minutes elapsed after
starting operation
(4)
When Ps ≤ 0.23 MPa
When Ps ≥ 0.27 MPa
During Heating
Operation
(5)
When 30 second elapses after first
startup operation when power ON at
TR < 26°C
When 8 minutes elapsed after
startup starting operation or when TR
≥ 26°C
(6)
When Ps ≤ 0.14 MPa
When Ps ≥ 0.19 MPa
Defrost
Operation
(7) When conditions for defrost satisfied
When 4-way valve is OFF during
defrost
(8) When conditions for defrost satisfied
When 2 minutes elapsed after 4-way
valve is ON after defrost completion
Содержание Estia RUA-CP1701H
Страница 15: ...Monobloc Outdoor Unit Service Manual 14 4 3 ESTIA hot water cylinder ...
Страница 18: ...Monobloc Outdoor Unit Service Manual 17 5 1 3 Wiring Diagram Sheet 6 ...
Страница 19: ...Monobloc Outdoor Unit Service Manual 18 5 1 4 Wiring Diagram Sheet 7 ...
Страница 20: ...Monobloc Outdoor Unit Service Manual 19 5 1 5 Wiring Diagram Sheet 8 ...
Страница 21: ...Monobloc Outdoor Unit Service Manual 20 5 2 General electrical connection 5 3 ESTIA hot water cylinder ...
Страница 24: ...Monobloc Outdoor Unit Service Manual 23 6 3 3 MCC 1599 interface PCB 6 3 4 MCC 1600 noise filter ...
Страница 28: ...Monobloc Outdoor Unit Service Manual 27 7 2 Refrigeration cycle system diagram Pumpless models ...
Страница 29: ...Monobloc Outdoor Unit Service Manual 28 Variable fixed speed hydraulic models ...
Страница 70: ...Monobloc Outdoor Unit Service Manual 69 ...
Страница 75: ...Monobloc Outdoor Unit Service Manual 74 ...
Страница 157: ...Monobloc Outdoor Unit Service Manual 156 16 2 21kW Fixed Speed Variable Speed Pumpless ...
Страница 160: ...Monobloc Outdoor Unit Service Manual 159 ...
Страница 161: ...Monobloc Outdoor Unit Service Manual 160 ...
Страница 162: ......
Страница 163: ......
Страница 164: ...TOSHIBA CARRIER EUROPE S A S Route de Thil 01120 Montluel France 1402410501R03 ...