2-16
SRW-5000/5500
ERROR-BB SY-FC INTERFACE ERROR
Description:
The communication error of FC CPU (IC1404 on FC-91 board) was detected.
Possible cause:
.
FC CPU (IC1404 on FC-91 board) trouble
.
When the FC CPU (IC1404 on FC-91 board) initialization is in abnormal
state.
Protecting operation:
Displays only this error.
ERROR-BC SY-50PIN INTERFACE ERROR
Description:
The communication error of CPU (IC320 on CP-378 board) for the 50-pin
parallel remote interface was detected.
Possible cause:
.
CPU (IC320 on CP-378 board) trouble
.
When the CPU (IC320 on CP-378 board) initialization is in abnormal state.
Protecting operation:
Displays only this error.
ERROR-FF SV UNDEFINE ERROR
Description:
The undefined error was detected in the servo system (servo control system).
Содержание SRW-5000
Страница 4: ......
Страница 12: ......
Страница 16: ......
Страница 58: ...1 42 SRW 5000 5500 d l l S G L 6 6 d d 4 8 3 7 2 6 0 1 5 9 ...
Страница 78: ......
Страница 194: ......
Страница 376: ......
Страница 398: ......
Страница 438: ...Printed in Japan Sony Corporation 2005 2 08 B P Company 2004 SRW 5000 SY SRW 5500 SY E 9 968 022 03 ...