8-36
SRW-5000/5500
A
B
C
D
E
1
2
3
4
TP102
TP401
TP400
E400
TP301
TP200
TP201
E100
LV200
TP100
TP101
A
CH-1
CH-1
A
8-8-2. LTC Playback Level Check
Tools
.
Oscilloscope:
TEKTRONIX TDS3054B or equivalent
.
Alignment tape: HR5-1B
Preparation
1. Check the settings for adjustment.
Refer to Section 8-8-1.
2. Check that the equipment has warmed up.
Before starting the adjustment, warm up the VTR and
oscilloscope through the power for 10 minutes or more.
Playback Level Check
1.
Set and connect the oscilloscope as follows:
CH-1: TP102/TC-104 (A-4), DC 100 mV/DIV
GND: E100/TC-104 (A-2)
TIME: 100
µ
s/DIV
2.
Insert the alignment tape HR5-1B.
3.
During play back the alignment tape in the PLAY
mode, check the level on the oscilloscope.
Specification: A
>
250 mV p-p
4.
Eject the alignment tape.
TC-104 Board (Side A)
8-8-3. LTC Recording Level Check
Tools
.
Oscilloscope:
TEKTRONIX TDS3054B or equivalent
.
Recording tape: BCT-SR series
n
For this recording tape, use a blank tape erased using the
tape eraser, etc. in advance.
Preparation
1. Conditions to be kept are:
.
Settings for adjustment. (Refer to Section 8-8-1.)
.
Warming up of equipment to be used (10 minutes or
more).
Recording Level Check
1.
Set and connect the oscilloscope as follows:
CH-1: TP100/TC-104 (A-1), DC 100 mV/DIV
GND: E100/TC-104 (A-2)
TIME: 100
µ
s/DIV
2.
Insert the recording tape.
3.
Check the level on the oscilloscope in the REC mode.
Specification: A = 80
±
10 mV p-p
4.
Eject the recording tape.
Oscilloscope
Oscilloscope
Содержание SRW-5000
Страница 4: ......
Страница 12: ......
Страница 16: ......
Страница 58: ...1 42 SRW 5000 5500 d l l S G L 6 6 d d 4 8 3 7 2 6 0 1 5 9 ...
Страница 78: ......
Страница 194: ......
Страница 376: ......
Страница 398: ......
Страница 438: ...Printed in Japan Sony Corporation 2005 2 08 B P Company 2004 SRW 5000 SY SRW 5500 SY E 9 968 022 03 ...