8-6
SRW-5000/5500
8-3-2. HDCAM SR RF Switching Position
Adjustment
Alignment tape:
HR2-1B
n
Rewind the alignment tape to the tape beginning in
advance.
1.
Activate the ALT MAINTENANCE menu, and
display the ALT SERVO ADJUST menu.
(HOME menu
→
[SFT]
+
[DIAG]
→
[SFT]
+
[F8]
→
[ALT]
→
[F4]
→
[ALT]
→
ALT SERVO AD-
JUST menu)
(For the ALT SERVO ADJUST menu, refer to Section
3-4-2.)
2.
Press the
[F5]
(RF SW POS SR) key to display the RF
SW POSITION menu.
3.
Press the
[SET]
key.
4.
Insert the alignment tape HR2-1B rewound to the tape
beginning.
.
Adjustment is executed automatically when the
alignment tape is inserted.
.
The message “Auto Adjust Complete” will be
displayed and the alignment tape will be ejected
automatically when this automatic adjustment is
completed normally.
n
The automatic adjustment may be failed even in
normal condition. If it is failed, turn off the power of
the unit once, and perform the adjustment again.
Saving the Data
5.
Press the
[F1]
(NVRAM CTL) key to display the NV-
RAM CONTROL menu.
6.
Select the “SAVE ALL DATA” by pressing the cursor
keys, then press the
[F10]
(EXIT) key to saving data.
.
The message “Save Complete” will be displayed
when this data save is completed normally.
7.
Press the
[ALT]
key once to exit the ALT SERVO
ADJUST menu. (Display the SERVO ADJUST
menu.)
8.
When the next adjustment (Section 8-3-4) is not
performed, exit the maintenance mode.
8-3-3. HDCAM RF Switching Position
Adjustment (SRW-5500 only)
Alignment tape:
HR2-1A
n
Rewind the alignment tape to the tape beginning in
advance.
1.
Activate the ALT MAINTENANCE menu, and
display the ALT SERVO ADJUST menu.
(HOME menu
→
[SFT]
+
[DIAG]
→
[SFT]
+
[F8]
→
[ALT]
→
[F4]
→
[ALT]
→
ALT SERVO AD-
JUST menu)
(For the ALT SERVO ADJUST menu, refer to Section
3-4-2.)
2.
Press the
[F6]
(RF SW POS HD) key to display the
RF SW POSITION menu.
3.
Press the
[SET]
key.
4.
Insert the alignment tape HR2-1A rewound to the tape
beginning.
.
Adjustment is executed automatically when the
alignment tape is inserted.
.
The message “Auto Adjust Complete” will be
displayed and the alignment tape will be ejected
automatically when this automatic adjustment is
completed normally.
n
The automatic adjustment may be failed even in
normal condition. If it is failed, turn off the power of
the unit once, and perform the adjustment again.
Saving the Data
5.
Press the
[F1]
(NVRAM CTL) key to display the NV-
RAM CONTROL menu.
6.
Select the “SAVE ALL DATA” by pressing the cursor
keys, then press the
[F10]
(EXIT) key to saving data.
.
The message “Save Complete” will be displayed
when this data save is completed normally.
7.
Press the
[ALT]
key once to exit the ALT SERVO
ADJUST menu. (Display the SERVO ADJUST
menu.)
8.
When the next adjustment (Section 8-3-4) is not
performed, exit the maintenance mode.
Содержание SRW-5000
Страница 4: ......
Страница 12: ......
Страница 16: ......
Страница 58: ...1 42 SRW 5000 5500 d l l S G L 6 6 d d 4 8 3 7 2 6 0 1 5 9 ...
Страница 78: ......
Страница 194: ......
Страница 376: ......
Страница 398: ......
Страница 438: ...Printed in Japan Sony Corporation 2005 2 08 B P Company 2004 SRW 5000 SY SRW 5500 SY E 9 968 022 03 ...