7-10
SRW-5000/5500
2. HDCAM Format (SRW-5500 only)
Tools
.
Cleaning tape:
BCT-HD12CL (Separately available)
.
Recording tape: BCT-HD series (Separately available)
n
Use the blank tape erased using the tape eraser, etc. in
advance or a new blank tape.
Preparation
Clean with the cleaning tape.
Insert the cleaning tape (BCT-HD12CL).
.
The EJECT button blinks, and the PLAY button light.
Then the cleaning tape is played back for about 10
seconds, before it is automatically ejected.
Recording Current Adjustment
1.
Activate the ALT MAINTENANCE menu, and
display the RF ADJUST menu.
(HOME menu
→
[SFT]
+
[DIAG]
→
[SFT]
+
[F8]
→
[ALT]
→
[F7]
→
RF ADJUST menu)
(For the RF ADJUST menu, refer to Section 3-4-5.)
2.
Press the
[F1]
(FMT SEL) key several times to select
the HDCAM.
3.
Press the
[F5]
(REC ADJ) key to display the REC
ADJUST menu.
4.
Insert the recording tape.
5.
To execute the automatic adjustment for the recording
current, press the
[F6]
(ALL CH ADJ) key then press
the
[SET]
key.
.
Message [Complete] will be displayed when this
adjustment is completed normally.
Saving the Data
n
Do not save the adjustment data if the automatic adjust-
ment was not completed properly.
6.
Press the
[F1]
(NVRAM CTL) key to display the NV-
RAM CONTROL menu.
7.
Select the “SAVE ALL DATA” by pressing the cursor
keys, then press the
[F10]
(EXIT) key to saving data.
.
The message “Save Complete” will be displayed
when this data save is completed normally.
8.
Eject the recording tape.
9.
Exit the maintenance mode.
Содержание SRW-5000
Страница 4: ......
Страница 12: ......
Страница 16: ......
Страница 58: ...1 42 SRW 5000 5500 d l l S G L 6 6 d d 4 8 3 7 2 6 0 1 5 9 ...
Страница 78: ......
Страница 194: ......
Страница 376: ......
Страница 398: ......
Страница 438: ...Printed in Japan Sony Corporation 2005 2 08 B P Company 2004 SRW 5000 SY SRW 5500 SY E 9 968 022 03 ...