A-67
Appendices
CP2E CPU Unit Software User’s Manual(W614)
A-2 A
u
xil
iar
y Area A
llocation
s b
y
Ad
dress
App
A-2-1 Read-only W
o
rds
A2
8
0
00
Pulse Output 0
Accel/Decel Flag
This flag will be ON when pulses are
being output from pulse output 0
according to an ORG, ACC, PLS2,
ITPL or IFEED instruction and the
output frequency is being changed in
steps (accelerating or decelerating).
ON: Accelerating or
decelerating
OFF: Constant speed
---
Cleared Refreshed
each cycle
during the
overseeing
processes.
01
Pulse Output 0
Overflow/Underflow
Flag
This flag indicates when an overflow or
underflow has occurred in the pulse
output 0 PV.
ON: Overflow or
underflow
OFF: Normal
---
Cleared
•
Refreshed
when the PV
is changed
by the INI
instruction.
•
Refreshed
when an
overflow or
underflow
occurs.
02
Pulse Output 0
Output Amount Set
Flag
ON when the number of output pulses
for pulse output 0 has been set with the
PULS instruction.
ON: Setting made
OFF: No setting
---
Cleared
•
Refreshed
when the
PULS
instruction is
executed.
•
Refreshed
when pulse
output stops.
0
3
Pulse Output 0
Output Completed
Flag
ON when the number of output pulses
set with the PULS, PLS2, ITPL or
IFEED instruction has been output
through pulse output 0.
ON: Output
completed
OFF: Output not
completed
---
Cleared Refreshed
at
the start or
completion of
pulse output.
04
Pulse Output 0
Output In-progress
Flag
ON when pulses are being output from
pulse output 0.
ON: Outputting
pulses
OFF: Stopped
---
Cleared Refreshed
when pulse
output starts or
stops.
05
Pulse Output 0
No-origin Flag
ON when the origin has not been
determined for pulse output 0 and goes
OFF when the origin has been
determined.
ON: Origin not
established
OFF: Origin
established
ON
ON Refreshed
each cycle
during the
overseeing
processes.
06
Pulse Output 0
At-origin Flag
ON when the pulse output 0 PV
matches the origin (0).
ON: Stopped at origin
OFF: Not stopped at
origin
---
Cleared Refreshed
each cycle
during the
overseeing
processes.
07
Pulse Output 0
Output Stopped Error
Flag
ON when an error occurred while
outputting pulses in the pulse output 0
origin search function.
The Pulse Output 0 Output Stop Error
code will be written to A444.
ON: Stop error
occurred
OFF: No error
---
Cleared
•
Refreshed
when origin
search
starts.
•
Refreshed
when a
pulse output
stop error
occurs.
A444
0
8
Pulse Output 0
Interrupt Feeding Flag
ON between Input Interrupt -
decelerating to stop when Interrupt
Feeding function (IFEED instruction) is
executing.
ON: Feeding
OFF: Not feeding
Cleared Cleared
•
Refreshed
when feed-
ing is com-
pleted.
•
Refreshed
when inter-
rupt feeding
is executing.
09
Pulse Output 0
Interrupt Feeding Error
Flag
ON if an overflow or underflow error
occurs during input interrupt or
specified number of pulse output, when
Interrupt Feeding function (IFEED
instruction) is executing.
ON: Overflow or
underflow
OFF: Normal
Cleared Cleared Refreshed
when interrupt
feeding is
executing.
Address
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words
Bits
Содержание SYSMAC CP Series
Страница 1: ...USER S MANUAL Cat No W614 E1 01 SYSMAC CP Series CP2E E D CP2E S D CP2E N D CP2E CPU Unit Software ...
Страница 3: ......
Страница 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Страница 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Страница 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Страница 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Страница 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Страница 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Страница 577: ......