Appendices
A-76
CP2E CPU Unit Software User’s Manual(W614)
A
3
92
04
Serial Port 1/
Built-in RS-2
3
2C Port
Error Flag
ON when an error has occurred at the
serial port 1 or built-in RS-2
3
2C port.
(Not valid in NT Link mode.)
ON: Error
OFF: Normal
Retained
Cleared
Refreshed
when error
occurs.
05
Serial Port 1/
Built-in RS-2
3
2C Port
Send Ready Flag
(No-protocol mode)
ON when the serial port 1 or built-in
RS-2
3
2C port is able to send data in
no-protocol mode.
ON: Able-to-send
OFF: Unable-to-send
Retained
Cleared
Written after
transmission
06
Serial Port 1/
Built-in RS-2
3
2C Port
Reception Completed
Flag (No-protocol
mode)
ON when the serial port 1 or built-in
RS-2
3
2C port has completed the
reception in no-protocol mode.
•
When the number of bytes was
specified: ON when the specified
number of bytes is received.
•
When the end code was specified:
ON when the end code is received or
256 bytes are received.
ON: Reception
completed
OFF: Reception not
completed
Retained
Cleared
Written after
reception
07
Serial Port 1/
Built-in RS-2
3
2C Port
Reception Overflow
Flag (No-protocol
mode)
ON when a data overflow occurred
during reception through the serial port
1 or built-in RS-2
3
2C port in
no-protocol mode.
•
When the number of bytes was
specified: ON when more data is
received after the reception was
completed but before RXD was exe-
cuted.
•
When the end code was specified:
ON when more data is received after
the end code was received but
before RXD was executed.
ON when 257 bytes are received
before the end code.
ON: Overflow
OFF: No overflow
Retained
Cleared
Refreshed
when error
occurs.
12
Serial Port 2/
Built-in RS-4
8
5 Port
Communications Error
Flag (CP2E N
3
0/40/60
or S
-type CPU Unit
only)
ON when a communications error has
occurred at the serial port 2 or built-in
RS-4
8
5 port. (Not valid in NT Link
mode.)
ON: Error
OFF: No error
Retained
Cleared
Refreshed
when error
occurs.
1
3
Serial Port 2/
Built-in RS-4
8
5 Port
Send Ready Flag
(No-protocol Mode)
(CP2E N
3
0/40/60 or
S
-type CPU Unit
only)
ON when the serial port 2 or built-in
RS-4
8
5 port is able to send data in
no-protocol mode.
ON: Able-to-send
OFF: Unable-to-send
Retained
Cleared
Written after
transmission
14
Serial Port 2/
Built-in RS-4
8
5 Port
Reception Completed
Flag (No-protocol
mode) (CP2E
N
3
0/40/60 or
S
-type CPU Unit
only)
ON when the serial port 2 or built-in
RS-4
8
5 port has completed the
reception in no-protocol mode.
•
When the number of bytes was
specified: ON when the specified
number of bytes is received.
•
When the end code was specified:
ON when the end code is received or
256 bytes are received.
ON: Reception
completed
OFF: Reception not
completed
Retained
Cleared
Written after
reception
15
Serial Port 2/
Built-in RS-4
8
5 Port
Reception Overflow
Flag (No-protocol
mode) (CP2E
N
3
0/40/60 or
S
-type CPU Unit
only)
ON when a data overflow occurred
during reception through serial port 2
or built-in RS-4
8
5 port in no-protocol
mode.
•
When the number of bytes was
specified: ON when more data is
received after the reception was
completed but before RXD was exe-
cuted.
•
When the end code was specified:
ON when more data is received after
the end code was received but
before RXD was executed.
ON when 257 bytes are received
before the end code.
ON: Reception
completed
OFF: Reception not
completed
Retained
Cleared
Refreshed
when error
occurs.
Address
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words
Bits
Содержание SYSMAC CP Series
Страница 1: ...USER S MANUAL Cat No W614 E1 01 SYSMAC CP Series CP2E E D CP2E S D CP2E N D CP2E CPU Unit Software ...
Страница 3: ......
Страница 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Страница 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Страница 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Страница 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Страница 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Страница 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Страница 577: ......