15 Ethernet
15-16
CP2E CPU Unit Software User’s Manual(W614)
15-4 FINS Communications
Note 1
Refer to the following diagram for the relation between message length and date length.
2
The FINS/UDP and FINS/TCP port numbers for CX-Programmer Auto Connection are always set to 9600, although
the FINS/UDP and FINS/TCP port numbers for user are set to other values.
15-4-1 FINS Communications Service Specifications
Item
Specification
Number of nodes
254
Message Length
1016 bytes max.
Date Length (See note 1.)
1004 bytes max.
Number of buffer
16
Protocol name
FINS/UDP method
FINS/TCP method
Protocol used
UDP/IP
TCP/IP
The selection of UDP/IP or TCP/IP is made by means of the FINS/UDP or FINS/TCP button
in Built-in Ethernet Tab in the CX-Programmer's PLC Setup.
Number of connections
---
3
for user, 1 for CX-Programmer auto connection
Port number (See note 2.)
9600 (default)
Can be changed.
9600 (default)
Can be changed.
Protection
No
Yes (Specification of client IP
addresses when unit is used as a server)
Other
Items set for each UDP port
• Broadcast
• Address conversion method
Items set for each connection
• Server/client specification
• Remote IP address specification
Server: Specify IP addresses of clients permitted to
connect.
Client: Specify remote Ethernet Unit (server) IP
address.
• Automatic FINS node address allocation:
Specify automatic allocation of client FINS node
addresses.
• Keep-alive:
Specify whether remote node keep-alive is to be used.
Internal table
This is a table of correspondences for remote FINS node addresses, remote IP addresses,
TCP/UDP, and remote port numbers. It is created automatically when power is turned ON to
the PLC or when the unit is restarted, and it is automatically changed when a connection is
established by means of the FINS/TCP method or when a FINS command received.
The following functions are enabled by using this table.
•
IP address conversion using the FINS/UDP method
•
Automatic FINS node address conversion after a connection is established using the
FINS/TCP method
•
Automatic client FINS node address allocation using the FINS/TCP method
•
Simultaneous connection of multiple FINS applications
10
b
ytes
2
b
ytes
Date length
Command code
1004
b
ytes max.
FI
N
S header
Message length: 1016
b
ytes max.
Содержание SYSMAC CP Series
Страница 1: ...USER S MANUAL Cat No W614 E1 01 SYSMAC CP Series CP2E E D CP2E S D CP2E N D CP2E CPU Unit Software ...
Страница 3: ......
Страница 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Страница 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Страница 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Страница 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Страница 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Страница 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Страница 577: ......