Appendices
A-72
CP2E CPU Unit Software User’s Manual(W614)
A
3
20
00
High-speed Counter 2
Range 1 Comparison
Condition Met Flag
These flags indicate whether the PV is
within the specified ranges when
high-speed counter 2 is being operated
in range-comparison mode for upper
and lower limits.
ON: PV in range
OFF: PV not in range
Cleared
Cleared
•
Refreshed
each cycle
during the
overseeing
processes.
•
Refreshed
when PRV
instruction is
executed to
read the
results of
range com-
parison.
•
Refreshed
when range
comparison
table is reg-
istered.
01
High-speed Counter 2
Range 2 Comparison
Condition Met Flag
02
High-speed Counter 2
Range
3
Comparison
Condition Met Flag
0
3
High-speed Counter 2
Range 4 Comparison
Condition Met Flag
04
High-speed Counter 2
Range 5 Comparison
Condition Met Flag
05
High-speed Counter 2
Range 6 Comparison
Condition Met Flag
0
8
High-speed Counter 2
Comparison
In-progress Flag
This flag indicates whether a
comparison operation is being
executed for high-speed counter 2.
ON: Being executed
OFF: Stopped
---
Cleared
Refreshed
when
comparison
operation
starts or stops.
09
High-speed Counter 2
Overflow/Underflow
Flag
This flag indicates when an overflow or
underflow has occurred in the
high-speed counter 2 PV. (Used with
the linear mode counting range only.)
ON: Overflow or
underflow
OFF: Normal
Cleared
Cleared
•
Refreshed
when an
overflow or
underflow
occurs.
•
Refreshed
when PV is
changed.
10
High-speed Counter 2
Count Direction
This flag indicates whether the
high-speed counter 2 is currently being
incremented or decremented. The
counter PV for the current cycle is
compared with the PV in last cycle to
determine the direction.
ON: Incrementing
OFF: Decrementing
---
Cleared
Setting used
for high-speed
counter, valid
during counter
operation.
A
3
21
00
High-speed Counter
3
Range 1 Comparison
Condition Met Flag
These flags indicate whether the PV is
within the specified ranges when
high-speed counter
3
is being operated
in range-comparison mode for upper
and lower limits.
ON: PV in range
OFF: PV not in range
Cleared
Cleared
•
Refreshed
each cycle
during the
overseeing
processes.
•
Refreshed
when PRV
instruction is
executed to
read the
results of
range com-
parison.
•
Refreshed
when range
comparison
table is reg-
istered.
01
High-speed Counter
3
Range 2 Comparison
Condition Met Flag
02
High-speed Counter
3
Range
3
Comparison
Condition Met Flag
0
3
High-speed Counter
3
Range 4 Comparison
Condition Met Flag
04
High-speed Counter
3
Range 5 Comparison
Condition Met Flag
05
High-speed Counter
3
Range 6 Comparison
Condition Met Flag
0
8
High-speed Counter
3
Comparison
In-progress Flag
This flag indicates whether a
comparison operation is being
executed for high-speed counter
3
.
ON: Being executed
OFF: Stopped
---
Cleared
Refreshed
when
comparison
operation
starts or stops.
Address
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words
Bits
Содержание SYSMAC CP Series
Страница 1: ...USER S MANUAL Cat No W614 E1 01 SYSMAC CP Series CP2E E D CP2E S D CP2E N D CP2E CPU Unit Software ...
Страница 3: ......
Страница 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Страница 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Страница 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Страница 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Страница 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Страница 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Страница 577: ......