14-39
14 Serial Communications
CP2E CPU Unit Software User’s Manual(W614)
14-6 C
onn
ectin
g the H
o
st C
o
m
puter
14
14-6-1 Ov
e
rvie
w
14-6 Connecting the Host Computer
Commands are sent from a host computer to the CP2E CPU Unit to read and write data. The serial
communications mode is set to Host Link.
Note
Because the built-in RS-4
8
5 port of the S
-type CPU Unit and the RS-4
8
5 port of CP2W-CIFD2/CIFD
3
use 2-wire connections, so they can only communicate in half duplex. Communications are not possible in
full duplex.
14-6-1 Overview
Command flow
Command type
Communica-
tions method
Configuration
Application
Remarks
Host computer
→
PLC
Host link
command
(C Mode)
Create frame
in the host
computer
and send the
command to
the PLC.
Receive the
response.
Directly connect the host com-
puter in a 1:1 or 1:N system.
Use this
method when
communicating
primarily from
the host com-
puter to the
PLC.
−
FINS command
(with Host Link
header and
terminator) sent.
Directly connect the host com-
puter in a 1:1 system or 1:N
system.
Use these
methods when
communicating
primarily from
the host com-
puter to PLCs
in the network.
The FINS com-
mand must be
placed between
a Host Link
header and ter-
minator and
then sent by the
host computer.
14-6-2 Flow of Operation
1
Connect the computer and CP2E CPU Unit using
RS-2
3
2C ports or RS-4
8
5 ports.
Set the PLC Setup (select Host Link for the serial
communications mode and set the communications
conditions) and transfer the PLC Setup from the
CX-Programmer to the CP2E CPU Unit.
2
Send the following commands from the host computer.
•
C-mode commands
•
FINS commands
3
Host link command
OR
Comm
a
nd
FI
N
S
Host Link
header
Host Link
terminator
OR
Comm
a
nd
Comm
u
nications
w
iring
PLC Set
u
p
Program from host
Содержание SYSMAC CP Series
Страница 1: ...USER S MANUAL Cat No W614 E1 01 SYSMAC CP Series CP2E E D CP2E S D CP2E N D CP2E CPU Unit Software ...
Страница 3: ......
Страница 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Страница 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Страница 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Страница 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Страница 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Страница 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Страница 577: ......