A-93
Appendices
CP2E CPU Unit Software User’s Manual(W614)
A-2 A
u
xil
iar
y Area A
llocation
s b
y
Ad
dress
App
A-2-2 Read/Wr
ite W
ords
A617
00
Serial Port 1/
Built-in RS2
3
2C Port
Communication Set-
tings
Display the present communication
settings of the serial port 1 or built-in
RS2
3
2C port. Reflect the PLC Setup
when power is turned ON.
Parity
0: Even
1: Odd
Retained
See
Function
column.
Refreshed
when power is
turned ON.
01
Parity
0: Yes
1: No
Retained
See
Function
column.
Refreshed
when power is
turned ON.
02
Stop bit
0: 2 bits
1: 1 bit
Retained
See
Function
column.
Refreshed
when power is
turned ON.
0
3
Data length
0: 7 bits
1:
8
bits
Retained
See
Function
column.
Refreshed
when power is
turned ON.
04
Start bit
0: 1 bit (fixed)
Retained
See
Function
column.
Refreshed
when power is
turned ON.
0
8
to
11
Communication
speed
0 hex: Default (9600)
3
hex: 1200
4 hex: 2400
5 hex: 4
8
00
6 hex: 9600
7 hex: 19200
8
hex:
38
400
9 hex: 57600
A hex: 115200
Retained
See
Function
column.
Refreshed
when power is
turned ON.
12
to
15
Communication
mode
0 hex: Default (Host
Link)
2 hex: NT link (1: N)
3
hex: Non-protocol
5 hex: Host Link
7 hex: Serial PLC
Link (Slave)
8
hex: Serial PLC
Link (Master)
9 hex: Modbus-RTU
Easy Master
D hex: Modbus-RTU
Slave
Retained
See
Function
column.
Refreshed
when power is
turned ON.
A61
8
00
Serial Port 2/
Built-in RS-4
8
5 Port
Communication Set-
tings
Display the present communication
settings of the serial port 2 or built-in
RS-4
8
5 port. Reflect the PLC Setup
when power is turned ON.
Parity
0: Even
1: Odd
Retained
See
Function
column.
Refreshed
when power is
turned ON.
01
Parity
0: Yes
1: No
Retained
See
Function
column.
Refreshed
when power is
turned ON.
02
Stop bit
0: 2 bits
1: 1 bit
Retained
See
Function
column.
Refreshed
when power is
turned ON.
0
3
Data length
0: 7 bits
1:
8
bits
Retained
See
Function
column.
Refreshed
when power is
turned ON.
04
Start bit
0: 1 bit (fixed)
Retained
See
Function
column.
Refreshed
when power is
turned ON.
Address
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words
Bits
Содержание SYSMAC CP Series
Страница 1: ...USER S MANUAL Cat No W614 E1 01 SYSMAC CP Series CP2E E D CP2E S D CP2E N D CP2E CPU Unit Software ...
Страница 3: ......
Страница 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Страница 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Страница 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Страница 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Страница 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Страница 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Страница 577: ......