Appendices
A-94
CP2E CPU Unit Software User’s Manual(W614)
A61
8
0
8
to
11
Serial Port 2 Built-in
RS-4
8
5 Port Commu-
nication Settings
Display the present communication
settings of the serial port 2 or Built-in
RS-4
8
5 Port. Reflect the PLC Setup
when power is turned ON.
Communication
speed
0 hex: Default (9600)
3
hex: 1200
4 hex: 2400
5 hex: 4
8
00
6 hex: 9600
7 hex: 19200
8
hex:
38
400
9 hex: 57600
A hex: 115200
Retained
See
Function
column.
Refreshed
when power is
turned ON.
12
to
15
Communication
mode
0 hex: Default (Host
Link)
2 hex: NT link(1: N)
3
hex: Non-protocol
5 hex: Host Link
7 hex: Serial PLC
Link (Slave)
8
hex: Serial PLC
Link (Master)
9 hex: Modbus-RTU
Easy Master
D hex: Modbus-RTU
Slave
Retained
See
Function
column.
Refreshed
when power is
turned ON.
A6
38
00
Serial Port 1(EX)
Modbus-RTU Easy
Master Execution
Flag (CP2E
N
-type CPU Unit
only)
Turn ON this bit to send a command
and receive a response for the serial
port 1(EX) using the Modbus-RTU
easy master function.
Note
This bit will be turned OFF auto-
matically by the system when
communications have been com-
pleted.
Turned ON: Execu-
tion started
ON: Execution in
progress.
OFF: Not executed
or execution
completed.
Retained
Cleared
---
DM Area
words for
serial
port
1(EX)
Mod-
bus-RTU
Easy
Master:
D1400 to
D1499
01
Serial Port 1(EX)
Modbus-RTU Easy
Master Normal End
Flag (CP2E
N
-type CPU Unit
only)
ON when one command has been
sent and the response received for the
serial port 1(EX) using the Mod-
bus-RTU easy master function.
ON: Execution nor-
mal.
OFF: Execution error
or still in
progress.
Retained
Cleared
Written after
reception.
02
Serial Port 1(EX)
Modbus-RTU Easy
Master Error End Flag
(CP2E N
-type
CPU Unit only)
ON when an error has occurred in
communications for the serial port
1(EX) using the Modbus-RTU easy
master function.
The error code is output to D1452 in
the DM fixed allocation words for Mod-
bus-RTU Easy Master.
ON: Execution error.
OFF: Execution
normal or still
in progress.
Retained
Cleared
Written when
error ends.
D1452
Address
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words
Bits
Содержание SYSMAC CP Series
Страница 1: ...USER S MANUAL Cat No W614 E1 01 SYSMAC CP Series CP2E E D CP2E S D CP2E N D CP2E CPU Unit Software ...
Страница 3: ......
Страница 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Страница 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Страница 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Страница 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Страница 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Страница 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Страница 577: ......