A-71
Appendices
CP2E CPU Unit Software User’s Manual(W614)
A-2 A
u
xil
iar
y Area A
llocation
s b
y
Ad
dress
App
A-2-1 Read-only W
o
rds
A
3
1
3
---
Error Contents for
Ethernet Errors
An error content is registered when a
built-in Ethernet error or Ethernet
setting table error occurs.
For details of the
error contents, refer
to
6-1-10 Non-fatal
Error
s
in the
CP2E
CPU Unit Hardware
U
s
er'
s
Manual
(Cat.
No. W61
3
).
Cleared
Cleared
Refreshed
when a
non-fatal error
occurs.
A
3
15.10
A
3
15
10
Built-in Etherent
Contents/Setup Error
Flag
ON when an error occurs in the
connection/setting of FINS/TCP, SNTP
and DNS server.
ON: Error
OFF: Normal
Cleared
Cleared
Refreshed
when a
non-fatal error
occurs.
A
3
1
3
A402.00
11
Logic Error in Setting
Tables
ON when an error occurs in the routing
table, IP address table and IP router
table.
The error code is stored in A
3
1
3
.
ON: Error
OFF: Normal
Cleared
Cleared
Refreshed
when a
non-fatal error
occurs.
A402.00
1
3
Option Board Error
Flag
ON when the Option Board is removed
while the power is being supplied.
ON when two Analog Option Boards
are mounted.
CPU Unit operation will continue and
the ERR/ALM indicator will flash.
Note
OFF when the error has been
cleared.
ON: Error
OFF: Normal
Cleared
Cleared
Refreshed
when a
non-fatal error
occurs.
A402.00,
A424
15
Backup Memory Error
Flag
ON when writing to the built-in Flash
Memory fails. CPU Unit operation will
continue and the ERR/ALM indicator
will flash.
Note
OFF when the error has been
cleared.
ON: Error
OFF: Normal
Cleared
Cleared
Refreshed
when a
non-fatal error
occurs.
A402.00
A
3
16
to A
3
17
---
High-speed Counter 2
PV
Contains the PV of high-speed counter
2.
A
3
17 contains the upper 4 digits and
A
3
16 contains the lower 4 digits.
Cleared
Cleared
•
Refreshed
each cycle
during the
overseeing
processes.
•
Refreshed
when PRV
instruction is
executed to
read PV.
•
Refreshed
when INI
instruction is
executed.
A
3
1
8
to
A
3
19
---
High-speed Counter
3
PV
Contains the PV of high-speed counter
3
.
A
3
19 contains the upper 4 digits and
A
3
1
8
contains the lower 4 digits.
Cleared
Cleared
•
Refreshed
each cycle
during the
overseeing
processes.
•
Refreshed
when PRV
instruction is
executed to
read PV.
•
Refreshed
when INI
instruction is
executed.
Address
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words
Bits
Содержание SYSMAC CP Series
Страница 1: ...USER S MANUAL Cat No W614 E1 01 SYSMAC CP Series CP2E E D CP2E S D CP2E N D CP2E CPU Unit Software ...
Страница 3: ......
Страница 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Страница 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Страница 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Страница 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Страница 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Страница 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Страница 577: ......