Appendices
A-60
CP2E CPU Unit Software User’s Manual(W614)
A50
04
Serial Port 1 (EX)
Communication Error
Flag
ON when a communication error has
occurred at the Serial Port 1 (EX).
ON: Error
OFF: Normal
Retained
Cleared
Refreshed
when error
occurs
05
Serial Port 1 (EX)
Send Ready Flag
(No-protocol Mode)
ON when the Serial Port 1 (EX) is able
to send data in no-protocol mode.
ON: Able-to-send
OFF: Unable-to-send
Retained
Cleared
Written after
transmission.
06
Serial Port 1 (EX)
Reception Completed
Flag (No-protocol
Mode)
ON when the Serial Port 1 (EX) has
completed the reception in no-protocol
mode.
•
When the number of bytes was
specified: ON when the specified
number of bytes is received.
•
When the end code was specified:
ON when the end code is received or
256 bytes are received.
ON: Reception
completed
OFF: Reception not
completed
Retained
Cleared
Written after
transmission.
07
Serial Port 1 (EX)
Reception Overflow
Flag (No-protocol
Mode)
•
ON when a data overflow occurred
during reception through the Serial
Port 1 (EX) in no-protocol mode.
•
When the number of bytes was
specified: ON when more data is
received after the reception was
completed but before RXD was exe-
cuted.
•
When the end code was specified:
ON when more data is received after
the end code was received but
before RXD was executed.
•
ON when 257 bytes are received
before the end code.
ON: Overflow
OFF: No overflow
Retained
Cleared
Written after
transmission.
A51
00 to
07
Serial Port 1(EX)
Polled Unit
Communications Flags
The corresponding bit will be ON when
the Serial Port 1(EX) is communicating
with Serial PLC Link mode.
Bits 0 to 7 correspond to Units 0 to 7.
ON: Communicating
OFF: Not
communicating
Retained
Cleared
Refreshed
when there is a
normal
response to
the token.
00 to
15
Serial Port 1(EX)
Reception Counter
(No-protocol mode
only)
Indicates (in binary) the number of
bytes of data received when the serial
port 1(EX) is in no-protocol mode.
Retained
Cleared
Refreshed
when data is
received.
A52
---
Pulse
Output 2
PV
Lower four
digits
Contain the number of pulses output
from the corresponding pulse output
port.
PV range:
8
000 0000 to 7FFF FFFF
hex (-2,147,4
83
,64
8
to 2,147,4
83
,647)
When pulses are being output in the
CW direction, the PV is incremented by
1 for each pulse.
When pulses are being output in the
CCW direction, the PV is decremented
by 1 for each pulse.
PV after overflow: 7FFF FFFF hex
PV after underflow:
8
000 0000 hex
Note
If the coordinate system is rela-
tive coordinates (undefined ori-
gin), the PV will be cleared to 0
when a pulse output starts, i.e.
when a pulse output instruction
(SPED, ACC, PLS2, ITPL or
IFEED) is executed.
Cleared
Cleared
•
Refreshed
each cycle
during the
overseeing
processes.
•
Refreshed
when the INI
instruction is
executed
(PV
change).
A5
3
Upper four
digits
A54
---
Pulse
Output
3
PV
Lower four
digits
A55
Upper four
digits
Address
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words
Bits
Содержание SYSMAC CP Series
Страница 1: ...USER S MANUAL Cat No W614 E1 01 SYSMAC CP Series CP2E E D CP2E S D CP2E N D CP2E CPU Unit Software ...
Страница 3: ......
Страница 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Страница 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Страница 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Страница 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Страница 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Страница 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Страница 577: ......