Appendices
A-90
CP2E CPU Unit Software User’s Manual(W614)
A569
00
Open Processing Flag
for Socket No.
3
Flag keeps ON during open
processing of socket No.
3
.
Finish open process, and then flag
turns OFF.
ON: During open
processing
OFF: Open
completed
---
Cleared
Refreshed at
the start or
completion of
open process
01
Reception
Progressing Flag for
Socker No.
3
Flag keeps ON during reception
processing of socket No.
3
.
Finish reception process, and then
flag turns OFF.
ON: Receiving
OFF: Reception
completed
---
Cleared
Refreshed at
the start or
completion of
reception
process
02
Transmission
Progressing Flag for
Socket No.
3
Flag keeps ON during transimission
processing of socket No.
3
.
Finish transmission process, and then
flag turns OFF.
ON: Sending
OFF: Transimission
completed
---
Cleared
Refreshed at
the start or
completion of
transmission
process
0
3
Close Processing
Flag for Socker No.
3
Flag keeps ON during close
processing of socket No.
3
.
Finish clsoe process, and then flag
turns OFF.
ON: During close
processing
OFF: Close
completed
---
Cleared
Refreshed at
the start or
completion of
close process
1
3
Data Received
Present/Not Present
Flag for Socket No.
3
Flag keeps ON when data is received
from the other node on an open TCP
socket.
Flag turns OFF when the reception
request is executed.
ON: Data reception
completed
OFF: Waiting for
reception
---
Cleared
•
Refreshed
after recep-
tion
•
Refreshed
when
reception
process is
requested
14
Result Storage Error
Flag for Socket No.
3
Flag keeps ON when any value other
than normal end (0000 hex) is stored
in the end code of the parameter area
of socket No.
3
.
Flag turns OFF when the next request
is received.
ON: Code other than
normal end is
stored
OFF: Normal end
---
Cleared
Refreshed
when socket
request
process is
completed
15
TCP/UDP Open Flag
for Socket No.
3
When open processing of socket No.
3
is completed, the flag turns ON.
When closing process is completed or
while closing, the flag turns OFF.
When open processing ends
abnormally, the flag remains OFF.
ON: Close com-
pleted
OFF: Open
completed
---
Cleared
Refreshed
when
open/close
process is
completed
A571
00
UDP Open Request
Switch for Socket
No.1
When the flag changes from OFF to
ON, UDP open processing is
executed.
When open process is completed, the
flag automatically turns OFF.
OFF to ON: UDP
open
---
Cleared
---
01
TCP Passive Open
Request Switch for
Socket No.1
When the flag changes from OFF to
ON, TCP passive open processing is
executed.
When open process is completed, the
flag automatically turns OFF.
OFF to ON: TCP
passive open
---
Cleared
---
02
TCP Active Open
Request Switch for
Socket No.1
When the flag changes from OFF to
ON, TCP active open processing is
executed.
When open process is completed, the
flag automatically turns OFF.
OFF to ON: TCP
active open
---
Cleared
---
0
3
Send Request Switch
for Socket No.1
When the flag changes from OFF to
ON, transmission processing is
executed.
When transmission process is
completed, the flag automatically turns
OFF.
OFF to ON: Send
---
Cleared
---
04
Receive Request
Switch for Socket
No.1
When the flag changes from OFF to
ON, reception processing is executed.
When reception process is completed,
the flag automatically turns OFF.
OFF to ON: Receive
---
Cleared
---
05
Close Request Switch
for Socket No.1
When the flag changes from OFF to
ON, close processing is executed.
When close process is completed, the
flag automatically turns OFF.
OFF to ON: Close
---
Cleared
---
Address
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words
Bits
Содержание SYSMAC CP Series
Страница 1: ...USER S MANUAL Cat No W614 E1 01 SYSMAC CP Series CP2E E D CP2E S D CP2E N D CP2E CPU Unit Software ...
Страница 3: ......
Страница 32: ...1 Overview 1 4 CP2E CPU Unit Software User s Manual W614 ...
Страница 44: ...3 CPU Unit Operation 3 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 116: ...6 I O Allocation 6 8 CP2E CPU Unit Software User s Manual W614 ...
Страница 144: ...7 PLC Setup 7 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 170: ...10 Interrupts 10 14 CP2E CPU Unit Software User s Manual W614 ...
Страница 200: ...11 High speed Counters 11 30 CP2E CPU Unit Software User s Manual W614 ...
Страница 272: ...12 Pulse Outputs 12 72 CP2E CPU Unit Software User s Manual W614 ...
Страница 278: ...13 PWM Outputs 13 6 CP2E CPU Unit Software User s Manual W614 ...
Страница 460: ...18 Programming Device Operations 18 28 CP2E CPU Unit Software User s Manual W614 ...
Страница 576: ...Revision 2 CP2E CPU Unit Software User s Manual W614 ...
Страница 577: ......