SISPM1040-582-LRT Quick Start Guide
33754 Rev. E
Page
1
of
2
SISPM1040-582-LRT
Managed Hardened PoE++ Switch (8) 10/100/1000Base-T PoE++
Ports + (2) 100/1000Base-X SFP Slot
Quick Start Guide
See the
Install
Guide
for important
Cautions
and
Warnings
, Features,
Specs, Back and Front Panel, LEDs, DIP Switch Settings, RESET button,
Installation, Mounting, Installing SFPs, Connecting Devices, DI/DO Relay,
Grounding, Connecting P1 and P2, Power Supply, Initial Config,
Troubleshooting, Warranty, PoE Modes, Compliance, and Tech Support.
Warning and Caution - Proper Installation and Operation (English): These devices are open-type devices that are to be installed in an
enclosure only accessible with the use of a tool, suitable for the environment. This equipment is suitable for use in Class I, Division 2,
Groups A, B, C, and D or non-hazardous locations only. WARNING – EXPLOSION HAZARD. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE
OR UNLESS THE AREA IS FREE OF IGNITIBLE CONCENTRATIONS.
Avertissement et mise en garde - Installation et fonctionnement corrects (français): Ces périphériques sont des périphériques de type
ouvert qui doivent être installés dans un enceinte uniquement accessible à l'aide d'un outil, adapté à environnement.
Cet équipement peut être utilisé dans la classe I, division 2, groupes A, B, C, et D ou des emplacements non dangereux seulement.
AVERTISSEMENT - RISQUE D'EXPLOSION. NE PAS SE DÉCONNECTER LORSQUE LE CIRCUIT EST VIVANT OU À MOINS QUE LA ZONE NE SOIT
LIBRE DE CONCENTRATIONS IGNIFIABLES.
Package Contents
: Verify you received one Switch with Terminal Block attached, one DB-9 to RJ-45 Cable, four adhesive
rubber feet, this document, and one DIN Rail mount kit.
Front Panel
:
The SISPM1040-582-LRT front panel ports, LEDs, Power Input terminal block, DI/DO terminal block,
CONSOLE port, DIP Switch, RESET button, and Ground screw.
LED Indicators
: The front panel LEDs provide switch and Ring status.
Power LEDs
indicate if the switch is powered up
correctly.
System LED
: indicates if the system is ready or not ready.
Alarm
LED
indicates if the system is normal or not.
Ring Master LED
and
Rapid Chain LED
indicate if the Rapid Ring is ready.
Port Status LEDs
indicate the current status of
each port. See the
Install
Guide
for details.
DIP Switch for Ring Settings
: The two-position DIP switch is labeled
RC
(1) (Rapid Chain) and
RM
(2) (Ring
Master). The DIP switch lets you avoid having to access the Web UI or CLI to configure a ring. See the
Install
Guide
for DIP switch setting details.
RESET
Button
: To reset the switch press RESET for 2~7 seconds; the SYS LED blinks green; Port status LEDs are Off.
To restore to defaults, press RESET for 7~12 seconds; the SYS LED blinks green; Port status LEDs are all ON.
Installation
:
Caution
: The switch is an indoor device. If used with outdoor devices such as outdoor IP cameras or
outdoor Wi-Fi APs, then it is strongly suggested to install a surge protector or surge suppressor to protect the switch.
Compliant with 802.3at in Environment A when using an isolated power supply. For other apps, see the
Install
Guide
.
These devices are open-type devices that are to be installed in an enclosure only accessible with the use of a tool,
suitable for the environment. This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-
hazardous locations only. “WARNING – EXPLOSION HAZARD. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE OR
UNLESS THE AREA IS FREE OF IGNITIBLE CONCENTRATIONS. Temperature code (T-Code) – T4.
Grounding Screw
:
ATTENTION
:
This case must be earth grounded. No DC input may be earth grounded. Use Isolated
Power Supply.
Caution
:
The switch is intended to be grounded to a well-grounded mounting surface such as a metal
plate. Install the grounding wire prior to connecting any other device to the Switch.
CAUTION
: Be sure to disconnect the
Switch from the power source before installing and wiring the device.
Warning
:
Turn the power off before connecting or disconnecting modules or wires. The correct power supply voltage is
listed on the product label. Check the voltage of your power source to make sure that you are using the correct voltage.
Do NOT use a voltage greater than what is specified on the product label.